Displaying the electrical label data
Electrical label data is also called permanent configuration data or archive information, which
includes the card name, serial number, MAC address, and vendor name.
•
Use the display device manuinfo command to display the electrical label data for the card in
each slot.
<Sysname> display device manuinfo
...
•
Use the display device manuinfo slot slot-number command to display the electrical label
data for the card in the specified slot.
<Sysname> display device manuinfo slot 0
...
Table 13 Command output
Field
DEVICE_NAME
DEVICE_SERIAL_NUMBER
MAC_ADDRESS
MANUFACTURING_DATE
The operation is not supported
on the specified board or subslot
Displaying the CPU usage statistics
Use the display cpu-usage command to display the CPU usage statistics for all cards.
<Sysname> display cpu-usage
Slot 0 CPU usage:
2% in last 5 seconds
2% in last 1 minute
1% in last 5 minutes
Slot 5 CPU usage:
1% in last 5 seconds
1% in last 1 minute
1% in last 5 minutes
Table 14 Command output
Field
Slot 0 CPU usage
1% in last 5 seconds
Description
Card type.
Card serial number.
MAC address of the card:
•
An MPU has a MAC address.
•
An LPU does not have a MAC address, and the field displays
NONE.
Manufacturing date of the card.
The display device manuinfo command is not supported on a card that
is virtualized through the MPU.
Description
CPU usage of the card in slot 0.
If the card in the slot has multiple CPUs, "Slot 0 CPU usage" displays the usage of
the master CPU of the card in slot 0, and "Slot 0 CPU 1 CPU usage" displays the
usage of the auxiliary CPU of the card in slot 0.
After a boot, the system calculates and records the average CPU usage rate
every five seconds.
This field displays the average CPU usage rate in the last five seconds.