Configuring Monitor Multicast Queue - Dell S3048-ON Configuration Manual

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

SessID
Source
Gre-Protocol FcMonitor
------
------
-----------
---------
0
Gi 1/1
A
N/A
0
Po 10
A
N/A
1
Vl 40
A
N/A
NOTE:
Source as VLAN is achieved via Flow based mirroring. Please refer section
In the following example, the host and server are exchanging traffic which passes through the uplink interface 1/1. Port 1/1 is the monitored
port and port 1/42 is the destination port, which is configured to only monitor traffic received on gigabitethernet 1/1 (host-originated
traffic).
Figure 91. Port Monitoring Example

Configuring Monitor Multicast Queue

To configure monitor QoS multicast queue ID, use the following commands.
1
Configure monitor QoS multicast queue ID.
CONFIGURATION mode
monitor multicast-queue queue-id
Dell(conf)#monitor multicast-queue 7
2
Verify information about monitor configurations.
EXEC mode
602
Port Monitoring
Destination
Dir
-----------
---
Gi 1/2
rx
No
Gi 1/2
rx
No
Gi 1/3
rx
No
Mode
Source IP
----
---------
Port
0.0.0.0
Port
0.0.0.0
Flow
0.0.0.0
Dest IP
DSCP
TTL
--------
----
---
0.0.0.0
0
0
0.0.0.0
0
0
0.0.0.0
0
0
Enabling Flow-Based
Drop
Rate
----
----
No
N/
No
N/
No
N/
Monitoring.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents