Recover From Stack Link Flaps; Recover From A Card Problem State On A Stack - Dell S3048-ON Configuration Manual

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

Recover from Stack Link Flaps

Stack link integrity monitoring enables units to monitor their own stack ports and disable any stack port that flaps five times within 10
seconds.
Dell Networking OS displays console messages for the local and remote members of a flapping link, and on the primary (master) and
standby management units as KERN-2-INT messages if the flapping port belongs to either of these units.
In the following example, a stack-port on the master flaps. The remote member, Member 2, displays a console message, and the master
and standby display KERN-2-INT messages.
To re-enable the downed stack-port, power cycle the offending unit.
Example of Console Messages About Flapping Link
---------------------MANAGMENT UNIT------------------------------
Error: Stack Port 50 has flapped 5 times within 10 seconds.Shutting down this st
ack port now.
Error: Please check the stack cable/module and power-cycle the stack.
10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times w
ithin 10 seconds.Shutting down this stack port now.
10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
---------------------STANDBY UNIT--------------------------------
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times within 10
seonds.Shutting down this stack port now.
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
---------------------MEMBER 2-----------------------------------
Error: Stack Port 51 has flapped 5 times within 10 seconds.Shutting down this stack port now.
Error: Please check the stack cable/module and power-cycle the stack.

Recover from a Card Problem State on a Stack

If a unit added to a stack has a different Dell Networking OS version, the unit does not come online and Dell Networking OS cites a card
problem error.
To recover, disconnect the new unit from the stack, change the Dell Networking OS version to match the stack, and then reconnect it to
the stack.
Example of Card Problem Error on a Stack - Different Dell Networking OS Versions
stack-1#show system brief
Stack MAC : 00:01:e8:8a:fd:6e
Reload Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType
Status
-----------------------------------------------------------
0
Standby
card problem S4810 unknown
1
Management online
2
Member
not present
3
Member
not present
4
Member
not present
5
Member
not present
6
Member
not present
7
Member
not present
8
Member
not present
9
Member
not present
10
Member
not present
11
Member
not present
820
Stacking
ReqTyp CurTyp
Version
64
S4810 S4810
8-3-10-223 64
Ports

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents