Displaying Uplink Failure Detection - Dell S3048-ON Configuration Manual

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

3/50
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Te
3/51
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 3/49
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 3/50
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 3/51
02:37:29: %RPM0-P:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to down: Gi 1/7
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Gi 1/7
02:37:29 : UFD: Group:3, UplinkState: DOWN
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed uplink state group state to down: Group 3
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Te
3/52
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 3/52
02:38:31 : UFD: Group:3, UplinkState: UP
02:38:31: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed uplink state group state to up: Group 3
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Te 3/49
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Te 3/50
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Te 3/51
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 3/52
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 3/49
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 3/50
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 3/51
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 3/52

Displaying Uplink Failure Detection

To display information on the UFD feature, use any of the following commands.
Display status information on a specified uplink-state group or all groups.
EXEC mode
show uplink-state-group [group-id] [detail]
group-id: The values are from 1 to 16.
detail: displays additional status information on the upstream and downstream interfaces in each group.
Display the current status of a port or port-channel interface assigned to an uplink-state group.
EXEC mode
show interfaces interface
interface specifies one of the following interface types:
For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
For a port channel interface, enter the keywords port-channel then a number.
If a downstream interface in an uplink-state group is disabled (Oper Down state) by uplink-state tracking because an upstream port is
down, the message error-disabled[UFD] displays in the output.
Display the current configuration of all uplink-state groups or a specified group.
EXEC mode or UPLINK-STATE-GROUP mode
(For EXEC mode) show running-config uplink-state-group [group-id]
(For UPLINK-STATE-GROUP mode) show configuration
866
Uplink Failure Detection (UFD)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents