Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Extend
("Extend the server from the
3.
on page 27) the server from the rack.
Remove the access panel
4.
Remove the air baffle (on page 31).
5.
Remove the fan cage.
6.
CAUTION: Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
IMPORTANT: For optimum cooling, install fans in all primary fan locations. For more
information, refer to the fan locations table
To replace the component, reverse the removal procedure.

FlexibleLOM

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some
internal circuitry remain active until AC power is removed.
Power down the server (on page 25).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Remove any attached network cables.
3.
Extend
("Extend the server from the
4.
on page 27) the server from the rack.
Remove the access panel
5.
Remove the primary PCIe riser cage (on page 33,
6.
rack" on page 26) or remove
("Access
panel" on page 30).
("Hot-plug
rack" on page 26) or remove
("Access
panel" on page 30).
("Remove the server from the
fans" on page 89).
("Remove the server from the
"PCIe riser cage
LED" on page 87).
Removal and replacement procedures 42