Hot-plug fan

The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server.
The server shuts down in the following temperature-related scenarios:
At POST:
The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the
o
cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly
shutdown and enters Standby mode.
The BIOS performs an orderly shutdown if two or more fans have failed.
o
The server performs an immediate shutdown if it detects a critical temperature level.
o