SawStop CNS175 Owner's Manual page 41

10 inch contractor saw
Table of Contents

Advertisement

Preparing Your Saw for Use
With the saw unplugged, use a Phillips screwdriver to remove the four screws on the cover of the contactor
box and remove the contactor box cover (see Fig. 41). Locate the contactor to which the black and white wires
from the power cord are attached and the ground connection to which the green wire from the power cord is
attached (see Fig. 42).
remove
contactor box
cover
Fig. 41
Disconnect the power cord from the contactor box by using a Phillips screwdriver to loosen the two screws at
the top of the contactor and removing the ends of the black and white power cord wires from the screws and
then removing the end of the green power cord wire from the ground connection (see Fig. 42 and 43).
ground
contactor
power cord
Fig. 42
Fig. 43
SawStop 10" Contractor Saw