3.
Care, Cleaning, and Maintenance
– Use the spatula to scrape away ash residue from the grate and scrape the edges of the burner pot base clean.
– All secondary air holes in the burner pot must be clear - clean them with a small screwdriver or drill bit if
necessary.
– Remove combustion residue from the burner pot with a vacuum cleaner. Vacuum the ash out of the primary air
tube (in the middle of the burner pot) vacuum out using the suction tube [5] provided.
BioWIN XL 350 NA
4
3
2
1
Fig. 121 Primary air pin, cone and ash wedge –
Fig. 123 Vacuuming out the primary air
tube using the suction tube
Assembly:
Important: Before inserting the primary air pin, vacuum out the primary air tube in the middle of the burner pot
again. Ensure there is no debris in the tube (this can cause damage to the ignition element!).
– Insert the primary air pin
Important: Groove must engage in anti-twist device – Fig. 124.
– Place the cone in the burner pot.
– Fit the ash wedge (BioWIN XL 350 NA only) on the burner pot in the right-hand corner, making sure the limit
stop is behind the screw head – Fig. 120.
– Note: Once cleaning is complete, the cleaning request for the combustion chamber and burner pot must be
reset on the InfoWIN
BioWIN XL 350
PLUS
– see section 2.8.1.1.
BioWIN XL 450 NA /600 NA
Fig. 122 Primary air pin, cone –
BioWIN XL 450 NA /600 NA
Fig. 124 Insert the primary air pin
52
1 ........... Primary air pin
2 ........... Cone, bottom part
3 ........... Cone, top part
3
4 ........... Ash wedge
5 ........... Suction tube
2
1

Hide quick links: