Windhager BioWIN XL Operating Manual page 41

Pellet central heating boiler/furnace
Table of Contents

Advertisement

2.
Operation
2.8.1.5 Probe switching
It is possible to set which probe(s)/zone(s) are used for transporting pellets from the pellet storage room. These
settings options are dependent on the service level setting in the "Type of pellet feed system" menu.
INFORMATION
Service level settings in the
"type of pellet feed system"
menu option.
No feed
USA, Canada and Europe
Suction turbine with 2 probes
USA, Canada and Europe
Suction turbine with 3 probes
Europe only!
Suction turbine with 4 probes
Europe only!
Suction turbine with 6 probes
Europe only!
Suction turbine with 8 probes
Europe only!
Suction turbine with mixer
1 Only displayed if there is a feed system installed with modifications on the service level by trained service personnel.
1
Only trained service personnel may perform system modifications on the service
level. (Directions for these settings can be found in the BioWIN XL installation in-
structions)
Setting options
for probe
switching
all probes
only probe 1
only probe 2
all probes
only probe 1
only probe 2
only probe 3
all probes
only zone 1
only zone 2
only probe 1
only probe 2
only probe 3
only probe 4
all probes
only zone 1
only zone 2
only probe 1
only probe 2
only probe 3
only probe 4
only probe 5
only probe 6
all probes
only zone 1
only zone 2
only probe 1
only probe 2
only probe 3
only probe 4
only probe 5
only probe 6
only probe 7
only probe 8
Description
Removal from both probes, automated switching
Removal from probe 1 only, no switching
Removal from probe 2 only, no switching
Removal from all 3 probes, automated switching
Removal from probe 1 only, no switching
Removal from probe 2 only, no switching
Removal from probe 3 only, no switching
Removal from zone 1 and zone 2, automated switching
Removal from probe 1 and probe 2, automated switching
Removal from probe 3 and probe 4, automated switching
Removal from probe 1 only, no switching
Removal from probe 2 only, no switching
Removal from probe 3 only, no switching
Removal from probe 4 only, no switching
Removal from zone 1 and zone 2, automated switching
Removal from probes 1-3, automated switching
Removal from probes 4-6, automated switching
Removal from probe 1 only, no switching
Removal from probe 2 only, no switching
Removal from probe 3 only, no switching
Removal from probe 4 only, no switching
Removal from probe 5 only, no switching
Removal from probe 6 only, no switching
Removal from zone 1 and zone 2, automated switching
Removal from probes 1-4, automated switching
Removal from probes 5-8, automated switching
Removal from probe 1 only, no switching
Removal from probe 2 only, no switching
Removal from probe 3 only, no switching
Removal from probe 4 only, no switching
Removal from probe 5 only, no switching
Removal from probe 6 only, no switching
Removal from probe 7 only, no switching
Removal from probe 8 only, no switching