Windhager BioWIN XL Operating Manual page 36

Pellet central heating boiler/furnace
Table of Contents

Advertisement

2.
Operation
Confirm the selected sub-menu "Feed operating mode" by
pressing the choose button – Fig. 70.
The factory setting for the "Feed operating mode" menu
item is "switched off".
With enable time: Select this option if the feed noise (suc-
tion turbine) can be heard or is disruptive in the living
area.
Functional description: The pellet feed is enabled for a
time period set by the user (see section 2.8.1.4) and is
automatically started at any time during the period it is
required. The integral fuel hopper is refilled from the
storage room at the end of the enable time, if necessary.
Tip: A complete fill uses about 264.4 lb /120 kg of pellets.
Burning duration is shown in the diagram below. The pel-
lets required during the set time must not exceed this value!
Burning duration with 264.4 lb / 120 kg pellets
BioWIN XL
BWE 350 NA
BWE 450 NA
BWE 600 NA
With start time: Select this option to start the feed at the
same time every day.
Functional description: If required at the set time, the
integral fuel hopper is filled from the storage room (see
section 2.8.1.4). Interim fills are also performed if the
filling amount is not sufficient for a full 24 hours.
Without time control: Select this option if the feed noise
(suction turbine) cannot be heard, or at a time when it
will not be disruptive in the living area.
Functional description: The pellet feed is automatically
turned on if required at any time.
INFORMATION
Use the arrow buttons to select the required sub-menu –
Fig. 71.
Press the save button to save the changed "Feed operating
mode" – Fig. 72. The display will show "Parameter is saved"
for a few seconds (Fig. 73) and then return to the previous
screen – Fig. 74.
Exit the menu or sub-menu by pressing the back button
(Fig. 74) or by waiting 10 minutes.
Burning duration at nominal output
15 h
12 h
9 h
It is only possible to select
one menu item at a time.
The "Time profile feed"
corresponding to the selec-
ted menu item can then be
set in section 2.8.1.4.
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Fig. 70
Feed operating mode
With enable time
With start time
Without time control
Switched off
Fig. 71
Feed operating mode
With enable time
With start time
Without time control
Switched off
Fig. 72
Parameter is saved
Fig. 73
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Fig. 74
36
choose
back
choose
back
save
back
(Animated symbol)
choose
back

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents