Windhager BioWIN XL Operating Manual page 15

Pellet central heating boiler/furnace
Table of Contents

Advertisement

1.
Important Information for System Operators
CAUTION
La belident GmbH Ar t.-N o. : W 08-0 5
WARNING
La belident GmbH Ar t.-N o. : W 08-0 5
WARNING
DANGER
WARNING
La belident GmbH Ar t.-N o. : W 08-0 5
WARNING
Caution
For supply connections, only use 10 AWG or larger wires acceptable for at least
176 °F (80 °C) on a GFCI circuit!
Necessary tasks
The heat exchanger, flue pipe, and chimney must be cleaned regularly to remo-
ve accumulated creosote and ash. Ensure that the heat exchanger, flue pipe, and
chimney are cleaned at the end of each heating season to minimize corrosion du-
ring the summer months. The appliance, flue pipe, and chimney must be in good
condition. These instructions also apply to a draft inducer, if used.
Pellet feed system: service, maintenance, and rules
The pellet feed system operates automatically. All service and maintenance must
be completed by trained specialists only. Do not alter the equipment or accesso-
ries in any way.
For use in combination with Windhager BioWIN XL pellet-fueled central heating
boiler/furnace only.
Do not use to transport any material other than wood pellet fuel listed on the boiler
nameplate or in the boiler manuals.
Do not use for vacuum cleaning.
The pellet feed system starts automatically and will make noise. People who are
easily startled or have cardiac problems should keep away.
Pellet feed unit: fire and explosion hazard
Can lead to serious injury/death! Ground suction hoses must be installed as de-
scribed in the installation instructions at every connection to avoid static sparking/
dust ignition. The pellet feed unit is for use with the day hopper only. The feed unit
must be braced, anchored, or strapped to avoid falling/shifting during an earthqua-
ke. Instructions can be obtained from your local Windhager dealer or wholesaler.
Pellet feed automatic changeover unit: Fire and explosion hazard
Fire and explosion hazard can lead to serious injury or death.
Do not use the pellet feed automatic changeover unit inside pellet storage room
or where there is a lot of dust present. Connect delivery hoses to pellet feed auto-
matic changeover unit as described in the installation instructions to avoid static
sparking or dust ignition.
Pellet feed automatic changeover unit: injury hazard by moving parts and elec-
tricity
Can lead to serious injury or death.
Device starts automatically. Device restarts automatically after power failure.
Do not remove cover.
This part should be serviced by trained personnel only.
Clearances and installation instructions
Minimum clearances from combustible or noncombustible construction:
2 inches left, 12 inches back, 24 inches top (right),
6 inches right side, 22 inches front.
Access to the back side is required to allow the service of parts such as the drain
valve, relief valve, and inspection fittings.
This unit is for dry indoor installation only. Not for installation on combustible floo-
ring. Not for installation in manufactured homes or mobile homes.
15