MAINTENANCE AND SERVICING

Procedures not specifically explained
in this manual must be performed
only by a qualified technician.
ACCIDENTAL OPERATION:
Turn the Power Switch of the tool to
its "OFF" position and unplug the
tool from its electrical outlet before
performing any inspection,
maintenance, or cleaning
procedures.
TO PREVENT SERIOUS INJURY
FROM TOOL FAILURE:
Do not use damaged equipment. If
abnormal noise or vibration occurs,
have the problem corrected before
further use.
Problem
Tool will not start
Tool operates
slowly or
erratically.
Tool does not
grind, sand or
brush effectively.
Follow all safety precautions whenever diagnosing or servicing the
tool. Disconnect power supply before service.
Item 65519
TO PREVENT SERIOUS
INJURY FROM

Troubleshooting

Possible Causes
1. No power at outlet.
2. Cord not connected.
3. Carbon Brushes may be worn or
damaged.
1. Carbon Brushes may be worn or
damaged.
2. Excess pressure applied to
workpiece.
1. Disc accessory may be loose on
Spindle. Check tightness of Outer
Flange Arbor Nut or threaded disc
accessory on Spindle.
2. Disc accessory may be damaged,
worn or wrong type for the
material.
For technical questions, please call 1-888-866-5797.

Cleaning, Maintenance, and Lubrication

1.
BEFORE EACH USE, inspect the general
condition of the tool. Check for loose
screws, misalignment or binding of moving
parts, cracked or broken parts, damaged
electrical wiring, and any other condition that
may affect its safe operation.
2.
Periodically blow dust and grit out of
the motor vents using dry compressed
air. Always wear safety glasses when
performing this maintenance operation.
3.
AFTER USE, clean external surfaces of the
tool with clean cloth. Never use solvents
or harsh cleaners as they may damage
the housing. To prevent electrical shock,
do not allow water or other liquids to
enter the motor vent holes in the Gear
Housing.
4.
WARNING! If the supply cord of
this power tool is damaged, it must be
replaced only by a qualified service
technician.
Likely Solutions
1. Check power at outlet.
2. Check that cord is plugged in.
3. Have Carbon Brushes replaced by a
qualified technician.
1. Have Carbon Brushes replaced by a
qualified technician.
2. Decrease pressure, allow tool to do
the work.
1. Be sure disc accessory is of correct
dimension and Outer Flange Arbor Nut
is tight.
2. Check condition and type of disc
accessory. Use only proper type of
disc accessory in good condition.