GE t60 Instruction Manual page 528

Ur series transformer protection system
Hide thumbs Also See for t60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 41 of 54)
ADDR
REGISTER NAME
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B500
Number of Status Indications in GGIO1
B501
IEC 61850 GGIO1 Indication operands (128 items)
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function
B
B5A1
IEC 61850 Configurable GOOSE ID
B5C2
Configurable GOOSE Destination MAC Address
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
B5C6
IEC 61850 Configurable GOOSE VLAN ID
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
B5C8
IEC 61850 Configurable GOOSE ConfRev
B5CA
IEC 61850 Configurable GOOSE Retransmission Curve
B5CB
Configurable GOOSE Dataset Items for Transmission
(64 items)
B60B
...Repeated for Module 2
B676
...Repeated for Module 3
B6E1
...Repeated for Module 4
B74C
...Repeated for Module 5
B7B7
...Repeated for Module 6
B822
...Repeated for Module 7
B88D
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (8 modules)
B900
Configurable GOOSE Dataset Items for Transmission
B940
...Repeated for Module 2
B980
...Repeated for Module 3
B9C0
...Repeated for Module 4
BA00
...Repeated for Module 5
BA40
...Repeated for Module 6
BA80
...Repeated for Module 7
BAC0
...Repeated for Module 8
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
BB06
Contact Input 1 Events
BB07
Contact Input 1 Debounce Time
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
BB68
...Repeated for Contact Input 14
BB70
...Repeated for Contact Input 15
BB78
...Repeated for Contact Input 16
BB80
...Repeated for Contact Input 17
BB88
...Repeated for Contact Input 18
BB90
...Repeated for Contact Input 19
BB98
...Repeated for Contact Input 20
BBA0
...Repeated for Contact Input 21
B-48
RANGE
8 to 128
---
0 to 1
---
---
0 to 7
0 to 4095
0 to 16383
1 to 4294967295
0 to 3
0 to 542
0 to 128
---
0 to 1
0 to 16
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
8
F001
---
1
F300
---
1
F102
---
---
F209
"GOOSEOut_x_"
---
---
F072
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F611
---
1
F232
---
1
F233
---
---
F205
---
1
F102
ms
0.5
F001
DEFAULT
8
0
0 (None)
0
4
0
0
1
3 (Relaxed)
0 (None)
0 (None)
"Cont Ip 1"
0 (Disabled)
20
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents