APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 11 of 23)
ADDRESS
FLEXANALOG NAME
8978
Xfmr Icd Angle
8979
Xfmr Icr Mag
8980
Xfmr Icr Angle
8981
Xfmr Harm2 Icd Mag
8982
Xfmr Harm2 Icd Angle
8983
Xfmr Harm5 Icd Mag
8984
Xfmr Harm5 Icd Angle
9008
Xfmr top-oil t° C
9009
Xfmr hst-spot t° C
9010
Xfmr agng fctr
9011
Xfmr daily LOL
9013
Xfmr acc LOL
9216
Synchchk 1 Delta V
9218
Synchchk 1 Delta F
9219
Synchchk 1 Delta Phs
9220
Synchchk 2 Delta V
9222
Synchchk 2 Delta F
9223
Synchchk 2 Delta Phs
10240
SRC 1 Ia THD
10241
SRC 1 Ia Harm[0]
10242
SRC 1 Ia Harm[1]
10243
SRC 1 Ia Harm[2]
10244
SRC 1 Ia Harm[3]
10245
SRC 1 Ia Harm[4]
10246
SRC 1 Ia Harm[5]
10247
SRC 1 Ia Harm[6]
10248
SRC 1 Ia Harm[7]
10249
SRC 1 Ia Harm[8]
10250
SRC 1 Ia Harm[9]
10251
SRC 1 Ia Harm[10]
10252
SRC 1 Ia Harm[11]
10253
SRC 1 Ia Harm[12]
10254
SRC 1 Ia Harm[13]
10255
SRC 1 Ia Harm[14]
10256
SRC 1 Ia Harm[15]
10257
SRC 1 Ia Harm[16]
10258
SRC 1 Ia Harm[17]
10259
SRC 1 Ia Harm[18]
10260
SRC 1 Ia Harm[19]
10261
SRC 1 Ia Harm[20]
10262
SRC 1 Ia Harm[21]
10263
SRC 1 Ia Harm[22]
10264
SRC 1 Ia Harm[23]
10273
SRC 1 Ib THD
10274
SRC 1 Ib Harm[0]
10275
SRC 1 Ib Harm[1]
10276
SRC 1 Ib Harm[2]
GE Multilin
UNITS
DESCRIPTION
Degrees
Transformer differential phase C current angle
Amps
Transformer restraint phase C current magnitude
Degrees
Transformer restraint phase C current angle
Amps
Transformer differential phase C second harmonic current magnitude
Degrees
Transformer differential phase C second harmonic current angle
Amps
Transformer differential phase C fifth harmonic current magnitude
Degrees
Transformer differential phase C fifth harmonic current angle
°C
Transformer top oil temperature
°C
Transformer hottest spot temperature
---
Transformer aging factor
---
Transformer daily loss of life
---
Transformer accumulated loss of life
Volts
Synchrocheck 1 delta voltage
Hz
Synchrocheck 1 delta frequency
Degrees
Synchrocheck 1 delta phase
Volts
Synchrocheck 2 delta voltage
Hz
Synchrocheck 2 delta frequency
Degrees
Synchrocheck 2 delta phase
---
Source 1 phase A current total harmonic distortion
Amps
Source 1 phase A current second harmonic
Amps
Source 1 phase A current third harmonic
Amps
Source 1 phase A current fourth harmonic
Amps
Source 1 phase A current fifth harmonic
Amps
Source 1 phase A current sixth harmonic
Amps
Source 1 phase A current seventh harmonic
Amps
Source 1 phase A current eighth harmonic
Amps
Source 1 phase A current ninth harmonic
Amps
Source 1 phase A current tenth harmonic
Amps
Source 1 phase A current eleventh harmonic
Amps
Source 1 phase A current twelfth harmonic
Amps
Source 1 phase A current thirteenth harmonic
Amps
Source 1 phase A current fourteenth harmonic
Amps
Source 1 phase A current fifteenth harmonic
Amps
Source 1 phase A current sixteenth harmonic
Amps
Source 1 phase A current seventeenth harmonic
Amps
Source 1 phase A current eighteenth harmonic
Amps
Source 1 phase A current nineteenth harmonic
Amps
Source 1 phase A current twentieth harmonic
Amps
Source 1 phase A current twenty-first harmonic
Amps
Source 1 phase A current twenty-second harmonic
Amps
Source 1 phase A current twenty-third harmonic
Amps
Source 1 phase A current twenty-fourth harmonic
Amps
Source 1 phase A current twenty-fifth harmonic
---
Source 1 phase B current total harmonic distortion
Amps
Source 1 phase B current second harmonic
Amps
Source 1 phase B current third harmonic
Amps
Source 1 phase B current fourth harmonic
T60 Transformer Protection System