3.3 Data Codes for Communication

Data communication function
Communication using MC protocol
Communication using fixed buffer
*1 Communication is performed in binary code regardless of the communication code setting.
3 - 3
NOTE
The following explains each of the transmission specification items.
[Connecting using the 10BASE-T]
Hub
Maximum 100m
Up to
4 levels
*1
*1 The value indicates the number of connectable stages when the repeater hub is used. Contact the manufacturer of
the switching hub for the number of connectable stages when using the switching hub.
This section explains the data codes used in the communication between the
Ethernet module and the external device or the PLC.
(1) The data codes used while communicating are listed below.
1) Ethernet module
Data can be communicated by selecting either binary code or ASCII code
in the data code setting of FX Configurator-EN or the PLC, as shown
below.
For more details about binary code/ASCII code changeover, refer to
Section 4.6, "Communication Settings".
Procedure exist
No procedure
NOTE
When sending/receiving e-mail, communication is performed using the data code
handled by each function, regardless of the setting of the communication data code.
[Connecting using the 100BASE-TX]
Hub
Maximum
100m
Maximum 5m
External device
Communication data code
Binary code
ASCII code
1
(*
)
MELSEC-F
Maximum
100m
Up to (2) levels are
allowed for cascade
connection.
Reference chapter
Chapter 8,9
Chapter 6
Chapter 7
: Selectable
: Cannot be communicated
*1
3 - 3