Download Print this page

Mitsubishi Electric FX3U-ENET Installation Manual

Hide thumbs Also See for FX3U-ENET:

Advertisement

Quick Links

JY997D15901B
FX
-ENET
3U
INSTALLATION MANUAL
Manual Number
JY997D15901
Revision
B
Date
November 2007
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and the manuals of
all relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product name described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective Nov. 2007
Specifications are subject to change without notice.
©
2005 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
3U
-ENET
INSTALLATION
JY997D15901
This manual
MANUAL
Describes the specifications,
FX
3U
-ENET
wiring, installation, maintenance,
JY997D18101
User's Manual
and operations of the FX
ENET.
Briefly describes the I/O
FX
Series
specifications, wiring, and
3U
JY997D18801
HARDWARE MANUAL
installation of the FX
3U
PLC.
Describes the I/O specifications,
FX
Series
JY997D16501
3U
wiring, installation, and
User's Manual
MODEL CODE:
maintenance of the FX
- Hardware Edition
09R516
PLC in detail.
FX
/FX
Series
3U
3UC
JY997D16601
Describes PLC programming for
Programming Manual
MODEL CODE:
basic/applied instructions and
- B a s i c & A p p l i e d
09R517
devices.
Instruction Edition
Briefly describes the I/O
FX
(D, DSS)
3UC
specifications, wiring, and
Series
JY997D28601
installation of the FX
3UC
HARDWARE MANUAL
PLC.
Describes the I/O specifications,
FX
Series
JY997D28701
3UC
wiring, installation, and
User's Manual
MODEL CODE:
maintenance of the FX
- Hardware Edition
09R519
PLC in detail.
FX Configurator-EN
Describes the operation method
JY997D20501
Operation Manual
of FX Configurator-EN.
Only this INSTALLATION MANUAL is supplied with the FX
-ENET.
3U
For more details regarding the FX
3U
/FX
3UC
Series hardware, PLC programming
commands, and special function blocks/units, refer to the appropriate manuals.
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi Electric
dealer from who you purchased this product.
How to obtain FX Configurator-EN
The parameter setting software, FX Configurator-EN is not supplied with this product.
Consult with the Mitsubishi Electric dealer from who you purchased this product
DESIGN
PRECAUTION
• Configure an interlock circuit in the sequence program so that the system
operates safely and uses the communication information in case of a
communication error.
• Do not bundle the communication cable or the 24V power supply together with the
main circuit or power line. Lay them at least 100mm (3.94") apart from each other.
Failure to do so may result in noise and malfunctions.
• Ensure that the unit and cable are not subjected to excessive force. Failure to do
so may result in wire damage/breakage or PLC failure.
Applicable Standard
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Models:
MELSEC FX
series manufactured
3U
-
FX
ENET
3U
Compliance with EC directive (CE Marking)
This notification and its contents do not guarantee that an entire mechanical module
will comply with the following standards.
Compliance to EMC and LVD directives for the entire mechanical module should be
checked by the user / manufacturer. For more details please contact your local
Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
Through direct testing (of the identified standards below) and design analysis (through
the creation of a technical construction file), the following products have shown
compliance to the European Directive for Electromagnetic compatibility (89/336/EEC)
when used as directed by the appropriate documentation.
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
series manufactured
3U
from August 1st, 2005 FX
-ENET
3U
Standard
may also
EN61131-2:2003
Compliance with all relevant aspects of the
Programmable controllers
standard.
- Equipment requirements and
• Radiated Emissions
tests
• Mains Terminal Voltage Emissions
• RF immunity
• Fast Transients
• ESD
• Conducted
• Surge
• Power magnetic fields
Notes for compliance to EMC regulation.
-
3U
The (FX
-ENET) must be installed in a shielded metal control panel.
3U
For more details please contact your local Mitsubishi Electric sales site.
1. Outline
Series
FX
-ENET is an Ethernet unit for the FX
/FX
3U
3U
3UC
is compliant with 100BASE-TX/10BASE-T and has the features as follows.
1) Data and programs within the PLC can be sent and received via Ethernet by using
GX Developer Ver.8.25B or later.
3U
Series
2) Communication between PLCs or with a general Ethernet device is possible by
fixed buffer communication. (TCP/IP or UDP/IP)
3) Users can develop custom software to communicate with the PLC by using MC
(MELSEC Communication) protocol (A-compatible 1E frame subset, for details,
refer to user's manual). (TCP/IP or UDP/IP)
4) E-mail can be sent and received. (SMTP or POP3 protocol)
5) The FX
3U
-ENET parameters can be set easily using FX Configurator-EN.
Series
6) The diagnostic functions of FX Configurator-EN enables easy diagnostics and
troubleshooting of the FX
3U
-ENET.
1.1 Incorporated Items
Series
3UC
Product
Ethernet unit for the FX
3U
Installation Manual (this manual)
Included items
Dust sheet
Label for indication of special function unit/block number
1.2 External Dimensions and Part Names
87(3.43")
9(0.36")
[1]
[2]
[3]
MASS(Weigth):0.3kg(0.66lbs)
[1] Direct mounting hole:2 holes of φ4.5
Used when ENET is directly mounted.
Not used when DIN rail is mounted.
[2] DIN rail mounting groove
[4] Extension cable
[6] INIT. LED
[8] SD LED
[10] ERR. LED
[12] Not available
[14] C1 to C8 LEDs
[16] Terminal block for power supply (24V DC) (M3 terminal block screw)
[17] Extension connector
Indications of LEDs
LED
RUN
Remark
RUN
INIT.
INIT.
100M
SD
100M
RD
ERR.
COM.ERR.
SD
POWER
RD
C1
C2
ERR
C3
C4
C5
COM ERR ● : Communication error
C6
C7
POWER
C8
C1 to C8
*The ERR LED illuminates in the following cases:
Series (Ver.2.21 or later) PLC that
- When an operational error occurs in the PLC CPU
- When an error is found in the Ethernet unit (H/W error)
Pin Configuration
The pin configuration of ENET RJ45 type modular jack (for category 5 or category 3)
is as follows:
Pin No.
1
2
3
4
8
1
5
6
/FX
Series PLC
3UC
7
8
Cables to be used
2-φ4.5
mounting
For 10BASE-T
holes
55(2.17")
(M4 screw)
[16]
[5]
For 100BASE-TX
RUN
INIT.
[6]
100M
SD
RD
ERR.
[7]
[4]
COM. ERR.
[8]
POWER
2. Installation
[9]
[17]
[10]
[11]
INSTALLATION
[12]
FX3U-ENET
PRECAUTIONS
10BASE-T/100BASE-TX
[13]
10BASE-T/100BASE-TX
C1
C2
C3
C4
• Make sure to cut off all phases of the power supply externally before attempting
C5
[14]
C6
C7
C8
installation or wiring work.
[15]
Failure to do so may cause electric shock.
Top cover is
removed
• Before attaching or replacing the main unit or extension unit, externally cut off
all phases of the power supply. If not, it may cause malfunctions or
misoperations.
INSTALLATION
PRECAUTIONS
• Use this product in the environment within the general specifications described
Unit:mm(inches)
in this manual.
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
or impacts, or expose it to high temperature, condensation, or rain and wind.
Doing so may cause electrical shock, fire, malfunctions, or damage or critical
deterioration to the product.
[3] DIN rail mounting hook
• When tightening the terminal screws, stay within the specified torque range.
[5] RUN LED
When tightened insufficiently, short-circuit or failure may occur. When tightened
[7] 100M LED
too much, the screws or the unit may be damaged, causing the unit disposal,
[9] RD LED
short-circuit, or failure.
[11] COM.ERR. LED
• Do not touch the conductive part or electric parts of this unit directly.
[13] POWER LED
Doing so may cause failure or malfunctions.
[15] RJ45 modular jack
• Install the unit on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
2.1 Mounting
Indication ( : Off, ●: On)
● : Normal operation
The FX
3U
: Operation error
2.1.1
● : Normal completion of initial processing
The FX
: Initial processing not yet completed
3U
● : 100Mbps
holes.
: 10Mbps not connected
A space of 1 to 2 mm (0.04" to 0.08") between each unit is necessary.
● : Sending data
: Not sending data
2.1.2
● : Receiving data
The FX
: Not receiving data
3U
● : Setting error*
1) Fit the upper edge of the DIN rail mounting
: No setting error
groove (fig. A) onto the DIN rail.
2) Push the unit onto the DIN rail.
: Normal communication
● : Power on
: Power off
● : Channel is open
: Channel is closed
2.1.3
When connecting to an FX
Before connections, turn off the power to the PLC.
1) Remove the extension device connector cover
of the main unit.
Signal
Direction
Contents
2) Fold and insert the extension cable in the
TD+
Out
+ side of sending data
corresponding connector as shown to the right.
− side of sending data
TD−
Out
3) Reattach the extension device connector cover
on the main unit.
RD+
In
+ side of receiving data
Not used
-
Not used
-
RD−
In
− side of receiving data
Not used
-
Not used
-
Category 5e, shielded twisted-pair cable
Category 5, shielded twisted-pair cable
Category 3, shielded twisted-pair cable
Category 5e, shielded twisted-pair cable
Category 5, shielded twisted-pair cable
, H
S, SO
, or NO
), flammable gas, vibration
2
2
2
2
-ENET can be mounted directly using screws or on a DIN rail (DIN46227).
Direct Mounting
-ENET can be mounted with M4 screws by using the direct mounting
→ For the mounting hole pitch information, refer to Section 1.2
DIN Rail Mounting
-ENET can be mounted on a DIN rail (DIN46227, 35mm width).
1)
A
2)
Procedure for connecting with the FX
Series PLC
3U
:
3U
1)
3)
2)

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3U-ENET

  • Page 1 JY997D15901B 1.2 External Dimensions and Part Names How to obtain manuals Cables to be used For the necessary product manuals or documents, consult with the Mitsubishi Electric Category 5e, shielded twisted-pair cable dealer from who you purchased this product. 2-φ4.5...
  • Page 2 • Place a label that warns of electrical shock (417-IEC-5036) on the enclosure of • Do not touch any terminals or connector while the PLC's power is on. nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be the final equipment.