Download Print this page

Mitsubishi Electric FX3UC-16MT/DSS Hardware Manual

Melsec-f fx3uc (d, ds, dss) series

Advertisement

Quick Links

Side
B
Side
Side
A
B
JAPANESE
ENGLISH
FX
(D, DS, DSS) SERIES
3UC
PROGRAMMABLE CONTROLLERS
HARDWARE MANUAL
Manual Number
JY997D50501
Revision
E
Date
December 2017
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX
(D,DS,DSS) Series User's Manual - Hardware Edition.
3UC
Refer to FX
Series User's Manual - Hardware Edition details.
3UC
Before use, read this manual and manuals of relevant products fully
to acquire proficiency in the handling and operating the product.
Make sure to learn all the product information, safety information,
and precautions.
And, store this manual in a safe place so that it can be taken out and
read whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective December 2017
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals, cut off all phases of
the power supply externally.
Failure to do so may cause electric shock.
JY997D50501E
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
• Do not change the program in the PLC from two or more
peripheral equipment devices at the same time. (i.e. from a
programming tool and a GOT)
Doing so may cause destruction or malfunction of the PLC program.
• Use the battery for memory backup correctly in FX
3UC
User's Manual - Hardware Edition.
- Use the battery only for the specified purpose.
- Connect the battery correctly.
- Do not charge, disassemble, heat, put in fire, short-circuit,
connect reversely, weld, swallow or burn the battery, or apply
excessive forces (vibration, impact, drop, etc.) to the battery.
- Do not store or use the battery at high temperatures or
expose to direct sunlight.
- Do not expose to water, bring near fire or touch liquid
leakage or other contents directly.
- Incorrect handling of the battery may cause heat excessive
generation, bursting, ignition, liquid leakage or deformation,
and lead to injury, fire or failures and malfunctions of facilities
and other equipment.
- When replacing the battery, make sure to use our specified
product (FX
-32BL).
3U
- When a battery error occurs ("BAT" LED is lit in red), follow the
description in FX
Series User's Manual - Hardware Edition.
3UC
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
• Turn off the power to the PLC before connecting or
disconnecting any extension cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, extension units/blocks, connector
conversion adapter, extension power supply units, special
adapters, and FX Series terminal blocks.
- Battery and memory cassettes
• Do not use the chemicals for cleaning.
• If there is the possibility of touching the PLC inside a control
panel in maintenance, make sure to discharge to avoid the
influence of static electricity.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for
the environmentally safe recycling and disposal of your device.
When disposing of batteries, separate them from other waste
according to local regulations.
(For details of the Battery Directive in EU countries, refer to
FX
Series User's Manual - Hardware Edition.)
3UC
TRANSPORTATION
AND STORAGE
PRECAUTIONS
• Before transporting the PLC, turn on the power to the PLC to
check that the BAT LED is off, and check the battery life.
If the PLC is transported with the BAT LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
TRANSPORTATION
AND STORAGE
PRECAUTIONS
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1 by using
dedicated packaging boxes and shock-absorbing palettes.
Failure to do so may cause failures in the PLC.
After transportation, verify operation of the PLC and check for
damage of the mounting part, etc.
• When
transporting
lithium
batteries,
transportation regulations.
(For details of the regulated products, refer to FX
Series
User's Manual - Hardware Edition.)
Associated manuals
How to obtain manuals
For the necessary product manuals or documents, consult with
your local Mitsubishi Electric representative.
Associated manuals
FX
(D, DS, DSS) Series PLC (main unit) comes with this
3UC
document (hardware manual).
For a detailed explanation of the FX
3UC
information on instructions for PLC programming and special
extension unit/block, refer to the relevant documents.
Manual name
Manual No.
FX
Series
JY997D28701
3UC
User's Manual
MODEL CODE:
- Hardware Edition
09R519
FX
3S
/FX
3G
/FX
3GC
/
FX
/FX
Series
JY997D16601
3U
3UC
Programming Manual
MODEL CODE:
- Basic & Applied
09R517
Instruction Edition
MELSEC-Q/L/F
SH-080782
Structured
MODEL CODE:
Programming Manual
13JW06
(Fundamentals)
FXCPU Structured
JY997D26001
Programming Manual
MODEL CODE:
[Device & Common]
09R925
FXCPU Structured
JY997D34701
Programming Manual
MODEL CODE:
[Basic & Applied
09R926
Instruction]
FXCPU Structured
JY997D34801
Programming Manual
MODEL CODE:
[Application
09R927
Functions]
FX Series User's
JY997D16901
Manual - Data
MODEL CODE:
Communication
09R715
Edition
FX
/FX
/FX
/
3S
3G
3GC
FX
/FX
Series
JY997D16701
3U
3UC
User's Manual
MODEL CODE:
- Analog Control
09R619
Edition
FX
/FX
/FX
/
3S
3G
3GC
FX
/FX
Series
JY997D16801
3U
3UC
User's Manual
MODEL CODE:
- Positioning Control
09R620
Edition
Certification of UL, cUL standards
FX
series main units, FX
3UC
power supply unit and FX
blocks supporting UL, cUL standards are as follows:
UL, cUL file number: E95239
Models:
MELSEC FX
FX
-MT/D
3UC
follow
required
Where  indicates: 16, 32, 64, 96
Series
3UC
FX
-16MR/D-T
3UC
FX
-232ADP(-MB)
3U
FX
-CF-ADP
3U
FX
-4AD-ADP
3U
FX
-3A-ADP
3U
FX
-4AD-PTW-ADP FX
3U
FX
-4AD-TC-ADP
3U
FX
-1PS-5V
3UC
Models:
MELSEC FX
FX
-16EX(-DS)
2NC
FX
-16EYT(-DSS) FX
2NC
FX
-16EX-T(-DS)
2NC
Series hardware and
Models:
MELSEC FX
FX
-8ER-ES/UL
2N
FX
-8EYR-ES/UL
2N
Description
FX
-8EYT-ESS/UL
2N
FX
-16EX-ES/UL
2N
Explains FX
Series
3UC
PLC specification details
FX
-16EYT-ESS/UL FX
2N
for I/O, wiring, installation,
and maintenance.
Compliance with EC directive (CE Marking)
Describes PLC
programming for basic/
This product complies with EC directive, however, this document
applied instructions STL/
does not guarantee that a mechanical system including this product
SFC programming and
will comply with EC directive.
devices.
Compliance to EMC directive and LVD directive of the entire
Programming methods,
mechanical system should be checked by the user / manufacturer.
specifications, functions,
For more details please contact the local Mitsubishi Electric sales
etc. required to create
site.
structured programs.
Caution for Compliance with EC directive
Devices, parameters, etc.
provided in structured
• Please use the FX
3UC
projects of GX Works2.
controllers while installed in conductive shielded control panels
under a general industrial environment.
Sequence instructions
• Programmable controllers are open-type devices that must be
provided in structured
installed and used within conductive control panels. Please secure
projects of GX Works2.
the control panel lid to the control panel (for conduction). Installation
within a control panel greatly affects the safety of the system and
Application functions
aids in shielding noise from the programmable controller.
provided in structured
• For the control panel, use the product having sufficient strength, fire
projects of GX Works2.
protectiveness and shielding property to an installation environment.
• 24 V DC of the power supply must be supplied from the circuit
Explains N:N link, parallel
double/reinforced insulated from the main power supply (MAINS).
link, computer link, no
protocol communication
Caution for compliance with the LVD directive
by RS instructions/FX
-
2N
(EN61010-2-201:2013) (*1)
232IF.
• To an external connection port other than AC power supply terminal
and AC input/output terminal, connect the circuit separated from a
Describes specifications
dangerous voltage by a double/reinforced insulation.
for analog control and
programming methods for
• Between the commons having the adjacent relay output
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
terminals, if an external power supply is higher than 120 V AC,
FX
Series PLC.
the insulation is basic. Therefore, when using 120 V AC or higher
3UC
external power supply and 30 V DC/AC or lower external power
Explains the specifications
supply between the adjacent commons, do not handle 30 V DC/
for positioning control of
AC or lower external power supply as a touchable part, (When
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
handling 30 V DC/AC or lower external power supply as a
FX
Series and
3UC
touchable part, add a basic insulation.)
programming procedures
series special adapter, extension
3U
/FX
series input/output extension
2N
2NC
series manufactured
3U(C)
FX
-MT/DSS
3UC
FX
-16MR/DS-T
3UC
FX
-485ADP(-MB)
3U
FX
-ENET-ADP
3U
FX
-4DA-ADP
3U
FX
-4AD-PT-ADP
3U
-4AD-PNK-ADP
3U
series manufactured
2NC
FX
-32EX(-DS)
2NC
-32EYT(-DSS)
2NC
FX
-16EYR-T(-DS)
2NC
series manufactured
2N
FX
-8EX-ES/UL
2N
FX
-8EYR-S-ES/UL
2N
FX
-8EX-UA1/UL
2N
FX
-16EYR-ES/UL
2N
-16EYS
2N
(D, DS, DSS) Series programmable

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3UC-16MT/DSS

  • Page 1 / manufacturer. SH-080782 disconnecting any extension cable. Structured specifications, functions, MODEL CODE: For more details please contact the local Mitsubishi Electric sales Failure to do so may cause equipment failures or malfunctions. Programming Manual etc. required to create 13JW06 Safety Precaution site.
  • Page 2 → For more details, refer to the FX Series User's Manual - Mitsubishi Electric recommends that shielded cables be used. If no Hardware Edition other EMC protection is provided, then users may experience temporary loss of accuracy between +10 %/-10 % in very heavy...
  • Page 3 Installation Location Procedures for installing to and detaching from Connection of power supply connector Notes DIN rail Install the PLC in an environment conforming to the generic Use the dedicated built-in power connector to supply power to the • When a dust proof sheet is supplied with an extension unit/ specifications (section 2.1), installation precautions and notes.
  • Page 4: Power Supply/Input/Output Specifications And Examples Of External Wiring

    Removal of the power cable Connection to input/output connector 3) Connectors for user-made input/output cables (available 2.6.2 Tightening Torque from Mitsubishi) 1) Turn the power supply OFF. The input/output connectors of the Main units (Connector type) Tighten the terminals to a torque of 0.22 to 0.25 N•m. Users should provide electric wires and a pressure bonding tool.
  • Page 5 Power supply specifications and example of 3.1.2 Example of external wiring (power type) Item Input specification (24 V DC) Notes external wiring Supply 24 V DC power to the main unit and FX -EX(-T) using -MT/D • Simultaneously turn on and off the power supplies of the main -16MR/D-T the dedicated connector.
  • Page 6 3.3.2 Handling of input terminal 2. Examples of sink input wiring (FX -MT/DSS, Output specifications and example of external 2) When using an instruction related to pulse train output or -16MR/DS-T) wiring positioning, make sure to set the load current to 10 to 100 mA 1) FX -MT/D, FX -16MR/D-T, FX...
  • Page 7: Terminal Layout

    3.4.4 Relay output specifications Cautions in input and output wiring 3.5.3 Cautions on relay output wiring Terminal Layout → For more details, refer to the FX Series User's Manual - → For more details, refer to FX Series User's Manual Notes Hardware Edition.
  • Page 8: For Safe Use

    -16EYT -32EYT Notch This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving Notch Notch industrial property rights which may occur as a result of using the contents noted in this manual.

This manual is also suitable for:

Fx3uc-32mt/dssFx3uc-64mt/dssFx2nc-16ex-dsFx2nc-32ex-dsFx2nc-16eyt-dssFx3uc-96mt/dss ... Show all