Replacing A Fan; Replacing A Power Supply - IBM TotalStorage DS4000 EXP100 Installation, User's, And Maintenance Manual

Storage expansion enclosure
Hide thumbs Also See for TotalStorage DS4000 EXP100:
Table of Contents

Advertisement

Lever
Pull ring
Figure 24. Replacing a power supply
2. Close the lever until the pull-ring latch locks in place. Make sure that the lever
locks into place in the expansion enclosure chassis. Then gently push the front
of the power supply to ensure that it is fully seated.
3. Repeat step 1 and step 2 to replace the second power supply.

Replacing a fan

Complete the following steps to replace the fan units that you removed before the
installation:
1. Place the fan in front of the fan bay.
2. Ensure that you move the fan latch in the same direction as the arrow before
you slide the fan all the way into the bay. If the fan does not go into the bay,
rotate it 180° (see Figure 25).
Figure 25. Replacing a fan
3. If the latch does not automatically lock when you have successfully inserted the
fan unit into the bay, pull back slightly on the fan and then push it in again until
the latch snaps into place.