23 Data Flash Memory
23.1 Overview
This LSI includes the data flash memory (data memory space (4 Kbytes: 1 Kbytes x 4 sectors)) that is rewritable by using a
special function register (SFR) programmatically.
23.1.1
Features
• Rewrite counts
*1
• Sector Erase
• Block erase
• Writing
*1
: One rewrite cycle includes both one time erase and one time write, it counts as one even if the erase is aborted.
Rewrite counts is counted as one even if you erase suspend.
FEUL610Q111
: 6000 times, V
=2.7 to 5.5 V@-20 to 85°C.
DD
: Erase of 512 words (1 Kbytes).
: Erase of 2 Kwords (4 Kbytes).
: 1-word (2 bytes) write.
ML610Q111/ML610Q112 User's Manual
Chapter 23 Data Flash Memory
23-1