Figure 8-3 shows one shot mode operation timing of timer 8 to B, E, F.
If timer out (TM9OUT and TMFOUT) is started with TnRUN of 1, timer out is inverted. Whenever the value of the count
value of TMnC and the preset value of a timer n data register (TMnD) is matched , the output is returned to the initial
value.
TnCK
TnRUN
TnSTAT
Write TMnC
TMnC
XX
TMnD
TMnINT
(n = 8 to B,E,F)
TMmOUT
(m=9,F)
Figure 8-3 One shot mode Operation Timing Diagram of Timer 8 to B,E,F
Note:
When the count value of TMnC and the value of a timer 8 to B,E,F data register (TMnD) are matched, a TnRUN bit is
cleared to "0" automatically.