Barcode Configuration > Single Label
When Single Label has been selected from the Code Combination drop-down list, the
Barcode Configuration window reveals related input fields.
Enter the appropriate information in the form as described below:
Field Name
Action/Definition
Code
Single Label has been selected.
Combination
No Read
Select Disable No Read Message, Global No Read Message, or Local No Read(s)
Message
Message from the drop-down list. The No Read condition occurs whenever a code
cannot be read or decoded.
Use 'Global
Select the check box to allow the Global No Read String to be used if no codes at all are
No Read
read. This option is not available when Global No Read Message is selected from the No
String'
Read Message drop-down list.
when No
Codes Read
Global No
Click
Read String
No Read Message is selected from the No Read Message drop-down list.
(max. 128
chars)
Disable No Read Message: The No Read Message is not transmitted.
Global No Read Message: The No Read String will be sent if the scanner is
unable to decode one or more barcodes in the reading phase.
Local No Read(s) Message: Do not use this option when working in Single
Label mode.
to activate the Text Entry Tool and create a string to be displayed when Global
4