5
Four DX8210
Barcode Readers;
left, right, and top
Conveyor
Figure 61 – Example Large Synchronized Network Reading Station
For applications having regular shaped packs, the default settings are sufficient, but for
Airport applications working in PackTrack Operating Mode, irregular shaped packs can
cause PS signal glitches resulting in false "packs too short" or "packs too close" errors.
To correct this, set the following Operating Modes parameters: Minimum Distance Between
Packs = 200 mm, Minimum Pack Length = 200 mm, Window Dimension = 200 mm.
230
Four DS8110
Barcode Readers;
front, back, and bottom
Photoelectric Sensor
Figure 62 – Compensating for Irregular-Shaped Packs