Datalogic DS8110 Reference Manual page 268

Hide thumbs Also See for DS8110:
Table of Contents

Advertisement

7
Error
Description
Severity
Code
130
Encoder
Warning
Timeout
131
Input 1
Error
Failure
132
No Phase
Error
Error
133
Input 2
Error
Failure
256
Explanation
Symptom
No encoder
- The scanner
(tachometer) is
may experience
detected in
an increase in
specified time. The
no-reads.
Encoder signal
provides the
- The scanner
scanner with belt
may start
speed and other
missing the
tracking
transmit point.
information.
This error will only
occur when the
scanner is in the
PackTrack mode.
The Primary PS
- The scanner will
(photoelectric
not go into
sensor) Input is
trigger.
stuck in the active
state (PackTrack
- No data will be
Mode).
transmitted to
the Host.
No Phase
"timeout" is
exceeded (On-Line
and PackTrack
Mode).
- Trigger must be
identified within
a specified time.
Secondary PS
- The scanner will
(photoelectric
not go into
sensor) Input
trigger.
Failure Stuck Active
(PackTrack Mode).
- No data will be
transmitted to
the Host.
DS8110 REFERENCE MANUAL
Troubleshooting
Action required
- Confirm that the
- Adjust the
belt is running.
encoder
(tachometer)
- Make sure the
mounting.
encoder
(tachometer)
- Adjust the
wheel is making
Encoder
a firm contact
Timeout setting
with the
(See section
conveyor.
4.5.9).
- Check the
Global Settings
| Diagnostics |
Encoder
Timeout setting
to confirm that
it is not set too
low (See section
4.5.9).
- Check the
- Realign the
alignment of
photoelectric
the
sensor.
photoelectric
sensor.
- Replace the
photoelectric
- Check the
sensor.
functionality of
the
photoelectric
sensor.
- Check the
- Realign the
alignment of
photoelectric
the
sensor.
photoelectric
sensor.
- Replace the
photoelectric
- Check the
sensor.
functionality of
the
photoelectric
sensor.