E-GENIUS
Field Name
Definition
PackTrack
Click Launch Wizard to open the PackTrack Calibration Wizard. See section 5.6
Calibration
PackTrack for the complete procedure for using the wizard to set up your barcode
Wizard
scanner.
Calibration
Y Adjustment
Adjustments
PackTrack
Calibration Item
Calibration
1-9
Coefficients
3. When you have finished making changes, click Update All to save all pending changes,
click Reset All to revert to all previously saved values, and click Reset Page to revert to
previous saved values on the current page.
PackTrack Calibration Wizard
PackTrack is a patented operating mode for Datalogic Omni-Directional Reading
Stations used to read and correctly assign codes read on different packs when placed in the
scanner Reading Area at the same time.
See section 5.6 PackTrack for the complete procedure for using the wizard to set up your
barcode scanner.
PackTrack Calibration
Enter the scanner adjustment from Y axis in millimeters in the
field provided. This is used to make fine adjustments to the
tested calibration (see section 5.6).
These non-editable fields display the PackTrack calculations.
0.