4
Field Name
Action/Definition
Heartbeat Message
Click
(max. 32 chars)
signal the beginning of the heartbeat message. Characters from NUL (00H) to ~
(7EH) can be used.
The Heartbeat Message (header) string must be different from the Heartbeat
Terminator string.
Heartbeat
Click
Terminator (max.
signal the end of the heartbeat message. Characters from NUL (00H) to ~ (7EH)
32 chars)
can be used.
The Heartbeat Terminator string must be different from the Heartbeat Message
(header) string.
Baud Rate
This is a read-only parameter. The default value Auto allows the Host to control
the data transmission speed of the Profibus network.
Data Flow
Select Disable, DAD Driver, or DPD Driver from the drop-down list. This
Control
implements a reliable transmission protocol between Fieldbus Master (PLC) and
Fieldbus Slave (SC5000 or Scanner Master) allowing specific functions such as
Synchronization, Fragmentation/Reassembling and Data Consistency.
Consistency
Select Disable or Enable from the drop-down list. This parameter is available only
when the Data Flow Control parameter is set to DAD or DPD Driver. If enabled, it
allows improving the overall communication robustness of the Fieldbus
network.
Profibus Settings
Node Address
Enter a node value in the field provided, to define the value that distinguishes this
node from all other nodes on the same link. Each node identifies a device within
the network.
Valid values are in the range 0 - 126.
Node Address 126 forces the SSA (Set Station Address) service which allows the
Fieldbus Master to assign the slave node address.
122
to activate the Text Entry Tool and create heartbeat header text to
to activate the Text Entry Tool and create Heartbeat Terminator text to
Flow Control Settings
DS8110 REFERENCE MANUAL