Datalogic DS8110 Reference Manual page 169

Hide thumbs Also See for DS8110:
Table of Contents

Advertisement

E-GENIUS
Field Name
Action/Definition
Secondary
Activation
Event
Activate On
Error
Primary
Deactivation
Event
Secondary
Deactivation
Event
Deactivate
On Clear
Error
Deactivation
Timeout
3. When you have finished making changes, click Update All to save all pending changes,
click Reset All to revert to all previously saved values, and click Reset Page to revert to
previous saved values on the current page.
Select a Secondary (Alternate) Activation Event from the drop-down
list (see below).
 None: The output is always in line state.
 Complete Read: The event occurs, if all selected codes are read.
 Partial Read: The event occurs, if less than the selected codes are
read.
 No Read: The event occurs, if no code is read.
 Trigger On: The event occurs, when a start event takes place
starting the reading phase.
 Trigger Off: The event occurs, when a stop event takes place
ending the reading phase.
 Multiple Read: The event occurs, if a code is read more than once
consecutively.
 Right/Match: The event occurs, if a code is successfully decoded
and matches the Match Code (Verifier Code).
 Wrong/No Match: The event occurs, if a code is successfully
decoded but does not match the Match Code (Verifier Code).
Select Disable or Enable from the drop-down list. If this parameter is
enabled, the output will activate when a diagnostic error message is
sent.
NOTE: When using this parameter, all other
activation events should be set to None.
Deactivation
Select a Primary Deactivation Event from the drop-down list (see
below).
 None: A deactivation event is NOT defined.
 Timeout: Indicates the maximum duration of the output pulse.
When selected, the Deactivation Timeout text field is revealed.
 Trigger On: The event occurs, when a start event takes place
starting the reading phase.
 Trigger Off: The event occurs, when a stop event takes place
terminating the reading phase.
Select a Secondary (Alternate) Deactivation Event from the drop-
down list (see below).
 None: A secondary deactivation event is NOT defined.
 Trigger On: The event occurs, when a start event takes place
starting the reading phase.
 Trigger Off: The event occurs, when a stop event takes place
terminating the reading phase.
Select Disable or Enable from the drop-down list. If this parameter is
enabled, the output will deactivate when the error is no longer present.
Enter the maximum duration of the output pulse in the text field provided.
Input a value from 40 to 15000 milliseconds.
0.