Poe System Settings - D-Link xStack DES-3200 Series Reference Manual

Layer 2 managed fast
Hide thumbs Also See for xStack DES-3200 Series:
Table of Contents

Advertisement

Class
0
1
2
3
4
For 802.3at capable devices, evaluate the table below, containing the correct power level per class and their
respective usage options. This feature provides power allocation of 0.1 Watt granularity, using the LLDP method.
Class
0
1
2
3
4
NOTE: Class 4 devices use the following equation:
Type 1 = 15.4 Watt.
Type 2 = 30 Watt.
To configure the PoE features on the Switch, click System Configuration > PoE.

PoE System Settings

This window is used to assign a power limit and power disconnect method for the whole PoE system. When the
total consumed power exceeds the power limit configured in this window, the PoE controller (located in the PSE)
disconnects the power to prevent overloading the power supply.
To view the following window, click System Configuration > PoE > PoE System Settings, as show below:
xStack® DES-3200 Series Layer 2 Managed Fast Ethernet Switch
Usage
Default
Optional
Optional
Optional
Reserved
Usage
Default
Optional
Optional
Optional
Optional
Minimum output power levels of PSE devices
15.4 Watt
4.0 Watt
7.0 Watt
15.4 Watt
Treat as Class 0
Minimum output power levels of PSE devices
15.4 Watt
4.0 Watt
7.0 Watt
15.4 Watt
15.4 or 30 Watt
Ptype=Icable x V Port_PSE min