Technical data

WEGA 501, 601

3.2
WEGA 501, 601
WEGA series
Switching steps
Welding current setting range
Duty cycle at 40C ambient temperature
45% DC
60% DC
100% DC
Duty cycle at 20C ambient temperature
52,5% DC
70% DC
100% DC
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Max. connected power
Workpiece lead
Recommended generator
power
Cosϕ
Weight
Dimensions (L/W/H in mm)
Insulation class/protection
classification
Ambient temperature
Machine/torch cooling
Constructed to standards
Internal cooling unit data
Max. tank capacity
Flow rate (max.)
Initial pressure (max.)
16
501DW
36 (3x12)
50 - 500 A
500 A
435 A
335 A
500 A
435 A
365 A
16,5 - 49,5 V
3 x 400V (+/- 15%)
50/60Hz
3x32A
27,5 kVA
2
95 mm
32 kVa
0,95
200 kg
960 x560 x 1010
H/IP 23
-20°C to +40°C
Fan/water
IEC 60974-1, -5, -10 /
9 l
5l/min
3.5bar
601DW
50 - 600A
600 A
520 A
400 A
600 A
520 A
440 A
16,5 - 57,5 V
36,7 kVA
2
95 mm
50 kVA
228 kg
/
Item No.: 099-004934-EWM01