Functional characteristics
Machine control – Operating elements
5.1.2.3

Setting the expert parameters

The parameter values set are preset in the JOB and can be modified if necessary.
Operating
element
5.1.2.4

Welding parameter ignition time "tZn" diagram

In the ignition time, the wire feed continues to run at creep speed after the arc is ignited;
the ignition behaviour is improved with the optimum setting.
The process described below is always used if there is a pause between welding processes of
not less than 1.5 seconds.
Legend with an explanation of symbols can be found in the MIG/MAG function sequences /
operating modes chapter.
36
Action
Result
Select expert parameters.
The key combination must be pressed within 3 seconds.
1 x
1 x
2 x
Select expert parameters:
n x
The selected parameter is shown on the display.
Set the parameter chosen.
Figure 5-5
NOTE
Gas pre-flow time "GvS" (0 s to 10 s)
Wire creep speed "On" 0.5 – 24 m/min
Ignition time "tZn" (0 ms to 500 ms)
NOTE
Item No.: 099-004934-EWM01