Quick Start Guide
3.0
Product certifications
Rev 1.11
3.1
European Directive information
A copy of the EU Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EU Declaration of Conformity can
be found at Emerson.com/Rosemount.
3.2
Ordinary Location Certification
As standard, the transmitter has been examined and tested to determine that
the design meets the basic electrical, mechanical, and fire protection
requirements by a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration (OSHA).
3.3
North America
The US National Electrical Code
permit the use of Division marked equipment in Zones and Zone marked
equipment in Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information is clearly defined in
the respective codes.
3.4
Hazardous locations certifications
USA
E5
FM Explosion-proof and Dust-Ignition-proof
Certificate: FM17US0170X
Standards: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T5
Canada
E6
CSA Explosion-proof and Dust-Ignition-proof
Certificate: 1063635
Standards: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966; CSA C22.2 No. 30-M1986;
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C,
Europe
E1
ATEX Flameproof
Certificate: FM12ATEX0065X
Standards: 60079-0:2012+A11:2013; EN60079-1:2007
Markings:
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
8
®
3810: 2005; ANSI/NEMA
(–50 °C ≤ T
≤ +85 °C); Type 4X
a
CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No.
213-M1987
D; (-50 °C ≤ T
≤ +85 °C)
a
II 2 G Ex d IIC T6...T1 Gb, T6(-50 °C ≤ T
T5...T1 (-50 °C ≤ T
≤ +60 °C),
a
(NEC) and the Canadian Electrical Code (CEC)
®
- 250: 1991
a
1180
August 2017
≤ +40 °C),