Download Print this page
Emerson Rosemount 499ACL-01 Quick Start Manual

Emerson Rosemount 499ACL-01 Quick Start Manual

Free chlorine sensor

Advertisement

Quick Start Guide
00825-0100-3499, Rev AB
September 2019
Rosemount
499ACL-01
Free Chlorine Sensor

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rosemount 499ACL-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson Rosemount 499ACL-01

  • Page 1 Quick Start Guide 00825-0100-3499, Rev AB September 2019 ™ Rosemount 499ACL-01 Free Chlorine Sensor...
  • Page 2 Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller, whichever period expires first. Consumables and Emerson.com/Rosemount...
  • Page 3: Table Of Contents

    September 2019 Quick Start Guide Services are warranted for a period of 90 days from the date of shipment or completion of the Services. Products purchased by Seller from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended by the original manufacturer. Buyer agrees that Seller has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement and shipping of the Resale Products.
  • Page 4 Quick Start Guide September 2019 Emerson.com/Rosemount...
  • Page 5: First Steps

    2. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Emerson immediately. Product description Figure 1-1: Rosemount 499ACL-01 Sensor Parts A. Membrane retainer B. Membrane assembly C. O-ring D.
  • Page 6 23567-00 CPVC and 1½-in. socket 122 °F (50 °C) 65 psig (549 Buna N kPa abs) ¾-in. NFPT 2-in. tee 915240-03 PVC and Buna 120 °F (49 °C) 60 psig (515 kPa abs) 915240-04 1-in. NFPT 915240-05 1½-in. NFPT Emerson.com/Rosemount...
  • Page 7 September 2019 Quick Start Guide Table 1-2: Other Specifications (continued) Type Wetted Process Maximum Maximum materials connection temperature pressure Low flow 24091-00 and Polycarbon- Compression 158 °F (70 °C) 90 psig cell 24091-01 ate/ fitting for (722 kPa abs) polyester, ¼-in.
  • Page 8: Install

    1 ft/sec (0.3 m/sec) Low flow cell (PN 24091-00) 8 to 15 gph (20 to 47 L/hr) Low flow cell (PN 24091-01) 2 to 3 gph (120 to 190 mL/min) Figure 2-1: Sensor Orientation Install sensor within 45 degrees of vertical. Emerson.com/Rosemount...
  • Page 9 September 2019 Quick Start Guide Figure 2-2: Flow Through 1½-in. Tee A. Union coupler B. 1-in. national pipe thread (NPT), two places C. Sensor body: Rosemount 499A D. 1-in. NPT flow cell adapter E. O-ring 2-222 F. 1½-in. sched 80 CPVC tee body Quick Start Guide...
  • Page 10 Quick Start Guide September 2019 Figure 2-3: Flow Through 2-in. Tee A. Union coupler B. Adapter C. 1-in. NPT (two places) D. Sensor body: Rosemount 499A E. O-ring 2-222 F. 2-in. sched 80 PVC tee body Emerson.com/Rosemount...
  • Page 11 September 2019 Quick Start Guide Figure 2-4: Low Flow Cell (PN 24091-00) A. Inches B. Millimeters C. Outlet D. Inlet Quick Start Guide...
  • Page 12: Wire

    Liquid Transmitter Wiring Diagrams. Figure 3-1: Rosemount 499ACL-01 Sensor Wiring to Rosemount 1056 and 56 Transmitters Table 3-1: Rosemount 499ACL-01 Sensor Wiring to Rosemount 1056 and 56 Transmitters Terminal Letter Wire color...
  • Page 13 September 2019 Quick Start Guide Table 3-1: Rosemount 499ACL-01 Sensor Wiring to Rosemount 1056 and 56 Transmitters (continued) Terminal Letter Wire color Description number Orange Cathode Figure 3-2: Rosemount 499ACL-01 Sensor Wiring to Rosemount 5081 Transmitter Table 3-2: Rosemount 499ACL-01 Sensor Wiring to Rosemount 5081 Transmitter...
  • Page 14 Quick Start Guide September 2019 Table 3-2: Rosemount 499ACL-01 Sensor Wiring to Rosemount 5081 Transmitter (continued) Terminal Letter Wire color Description number White/red RTD sense RTD in Reference guard Reference in Clear Solution ground pH guard pH in -5 V...
  • Page 15 September 2019 Quick Start Guide Figure 3-3: Rosemount 499ACL-01 Sensor Wiring to Rosemount 1066 Transmitter Note Connect clear shield wires to solution ground terminal on TB 2. Use wire nut and pigtail if necessary. A. Orange B. Cathode C. Anode D.
  • Page 16 Quick Start Guide September 2019 Figure 3-4: Rosemount 499ACL-01-01-54-VP Sensor Pin-out Diagram (Top View of Connector End of Sensor) Table 3-3: Pin-out Diagram Terminal number Description Cathode RTD sense Anode RTD return RTD in When making a connection through a junction box (PN 23550-00), wire point-to-point.
  • Page 17: Calibrate

    September 2019 Quick Start Guide Calibrate Zero point calibration Even in the absence of free chlorine, the sensor generates a small signal called the zero current. Failing to correct for the zero current can introduce a bias, particularly if the chlorine concentration is small (<0.4 ppm). Zero the sensor when it is first placed in service and every time the fill solution is changed.
  • Page 18 Refer to the manual for the transmitter you are using (Rosemount 56, 1056, 5081, or 1066). 7. After calibration, go to the Diagnostics menu and check the sensitivity. The sensitivity should be between 300 and 700 nA/ppm. For more information, refer to the transmitter manual. Emerson.com/Rosemount...
  • Page 19: Maintenance

    September 2019 Quick Start Guide Maintenance Periodic maintenance and cleaning are required for best performance of the sensor. Generally, the membrane and fill solution should be replaced every one to three months. If the sensor is being used in water having conductivity less than about 100 µS/cm, it might be necessary to replace the fill solution (but not the membrane) more often.
  • Page 20 A sharp probe may puncture the bladder and destroy the sensor. Do not use a sharp probe. 19. Gently press the probe against the bladder several times to force liquid through the holes at the base of the cathode stem. Keep Emerson.com/Rosemount...
  • Page 21 September 2019 Quick Start Guide pressing the bladder until no air bubbles can be seen leaving the holes. Be sure the holes remain covered with electrolyte solution. 20. Place a drop of electrolyte solution on the cathode; then place the membrane assembly over the cathode.
  • Page 22: Accessories

    O-ring, Viton 2-014 33521-00 Membrane retainer 23501-08 Free chlorine membrane assembly: includes one membrane assembly and one O-ring 23502-08 Free chlorine membrane kit: includes three membrane assemblies and three O-rings 9210356 #4 free chlorine sensor fill solution, 4 oz (120 mL) Emerson.com/Rosemount...
  • Page 23 September 2019 Quick Start Guide Quick Start Guide...
  • Page 24 Linkedin.com/company/Emerson- Automation-Solutions The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a twitter.com/rosemount_news mark of one of the Emerson family of companies. Facebook.com/Rosemount All other marks are the property of their youtube.com/RosemountMeasurement respective owners.