ProMinent DULCOMARIN II Assembly And Installation Manual page 41

Multi-channel measuring and control system/swimming pool controller and disinfection controller dxca
Table of Contents

Advertisement

A module (control module) DXMaA
Description
Terminal
identifier
Relay output 1
R1
Relay output 2
R2
Relay output 3
R3
Contact input 1
K1
Contact input 2
K2
Contact input 3
K3
Current output
I out 1
0/4-20mA 1
Current output
I out 2
0/4-20mA 2
Current output
I out 3
0/4-20mA 3
Current output
I out 4
0/4-20mA 4
Ter‐
Pole Function*
minal
no.
1
+
Control acid pump
or
2
-
Control alkali
pump
3
+
Control chlorine
pump
4
-
Control acid pump
Control redox
pump
5
+
Control flocculant
pump
6
-
Control chlorine
pump
Control redox
pump
7
+
Pump error
or
8
-
Filling level
9
+
Pump error
or
10
-
Filling level
11
+
Pump error
or
12
-
Filling level
13
+
pH plotter connec‐
tion
14
-
15
+
Redox plotter con‐
nection
16
-
17
+
Chlorine free
plotter connection
18
-
19
+
Comb. chlorine
plotter connection
20
-
or
Temperature
plotter connection
Wiring diagram DULCOMARIN® II compact
Cable
Drill hole
no.
Size
d5
13/M12
d5
14/M12
d5
15/M12
d4
4/M20
d4
4/M20
d4
5/M16
d4
6/M16
d4
6/M16
d4
/M16
d4
7/M16
Remarks
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
Guide 2 cables
through multiple
seal inserts 2x4
47