Assembly and installation
24
NOTICE!
Cable strain relief
With control panel mounting, the cables must be
routed in a site-provided cable duct to ensure strain
relief.
1.
Plan which threaded holes shall be broken out (mark the
desired threaded holes)
CAUTION!
When breaking open the threaded holes, avoid
pushing the screwdriver deep into the housing. Parts
inside the device could be damaged.
Fig. 10: Breaking out threaded holes
2.
To break out the threaded holes, punch the slit in the middle
of the threaded holes using a screwdriver (tip width 3.5 - 4
mm, see Fig. 10) and lever the material out
3.
De-burr the resulting edges
A0494