Procedure With Dxm Housing (Small); Mounting (Mechanical) - ProMinent DULCOMARIN II Assembly And Installation Manual

Multi-channel measuring and control system/swimming pool controller and disinfection controller dxca
Table of Contents

Advertisement

5.2 Procedure with DXM housing (small)

5.2.1 Mounting (mechanical)

For wall mounting, please observe the
following steps:
6.
Check the cabling using the wiring diagram
Mounting materials (contained in the scope of delivery):
1 x wall/pipe bracket
n
2 x half-round head screws 5x45 mm
n
2 x washers 5.3
n
2 x rawl plug Ø 8 mm, plastic
n
1 x sealing cap
n
1 x safety screw (PT)
n
2
1
1.
Remove the wall/pipe bracket from the DXM
2.
Pull the two snap hooks outwards and push them upwards
(1)
3.
Fold the wall/pipe bracket away and pull it out (2) in a down‐
wards direction
4.
Mark two drill holes diagonal to each other by using the wall/
pipe bracket as a drilling template
5.
Drill the holes: Ø 8 mm, d = 50 mm