ProMinent DULCOMARIN II Assembly And Installation Manual page 40

Multi-channel measuring and control system/swimming pool controller and disinfection controller dxca
Table of Contents

Advertisement

Wiring diagram DULCOMARIN® II compact
M module (measurement module) DXMaM
Description
Terminal
identifier
Temp. input
RTD
Pt1000/100
Redox input 1
ORP(pH)
Potential equali‐
Pot.1
sation 1
Potential equali‐
Pot.2
sation 2
pH input 2
ORP(pH)
Contact input 1
K1
Contact input 2
K2
Contact input 3
K3
46
Comprehensive module populating options are listed in the "Sup‐
plementary instructions DULCOMARIN® II, DXMa Modules".
Ter‐
Pole
Function
minal
no.
1
+
Temp.- sensor
2
-
3
Ref.
Redox - sensor
4
meas
sig.
5
6
pH - sensor
7
Ref.
8
meas
sig.
9
+
Fault sample
water
10
-
11
+
Pause (back‐
washing)
12
-
13
+
ECO!Mode
14
-
Cable
Drill hole
Remarks
no.
Size
d 5
1/M16
d3/d5
2/M20
Guide cable
through multiple
seal inserts 2x5
or 2x4
11/M12
11/M12
d3/d5
2/M20
Guide cable
through multiple
seal inserts 2x5
d4
3/M16
Guide cable
through multiple
seal inserts 2x4
d4
3/M16
"
d4
12/M12

Advertisement