Gas Line Connection; Electrical Connection - Pitco Frialator SF14 UFM Installation & Operation Manual

Installation, operation and maintainance manual for gas fryers with solo filter
Table of Contents

Advertisement

1.4.2.2
Gas Line Connection
-
Connect the fryer to the gas supply line with a oonnector that
amplies with the Standard for Connectors for Movable Gas Appliances (ANSI Z21.69-1987). If you
are installing a fryer with casters use a quick disoonnect refer to the Quick Disconnect installation
instruction, 1.4.2.3. Connect the gas line to the fryer using a pipe joint sealant that is resistant to
liquefied petroleum. If the fryer was disoonnected during the fuel line testing, use a solution of soap
and water to leak test the new oonnection.
NEVER use an adaptor to make a smaller gas supply line fit the
connedion. This may not allow proper gas flow for optimum
operation, resulting in poor cooker performan~..
1.4.2.3
OuickDjsa)nnectGasConnection-Gasfryers
equipped with casters must be installed with connedors
that comply with the Standud for Connectors for Movable
Gas Appliances, ANSI 221.69-1987, and Addenda
Z21.69A-1989. This connection should include a quick
disconned device that complies with the Standard for
Quick Disamnect Devi~ for Use With Gas Fuel, ANSI
Z21.41-1989. When installing a quick disoonnect you
must also install a means for limiting the movement of the
fryer. This device will prevent the gas line or the quick
disronnect from being strained. The restraining device
should be attached to the cooker on the back panel as
shown in the illustration. The quick disconnect, hose, and
restraining device can be obtained from your dealer.
1.4.2.4
Fuel SYR~IX Line Leak and Pressure Testine
-
The fuel supply system must be tested
before the fryer is used. If the fuel line is going to be tested at a pressure greater than (»1/2 PSIG
(3.45 kPa), make sure that the fryer is disamneded from the fuel line. If the fuel line is to be tested
at a pressure equal to or less than (s) 1/2 PSIG (3.45 kPa), the fryer can be
COft-!!e-m.rl
but the unit's
gas valve must be shut. Test all gas line connections for leaks with a solution of soap and water when
pressure is applied.
1.4.3 Electrical Connection
The electrical servi~ used by the fryer must oomply with local cx>des. If there are no local a>des that
apply, refer to the National Electrical Code (NEC) to install the servi~. In Canada refer to CSA
Standard C22.1 and local codes. Wiring diagrams are provided inside the fryer door. The power
requirements for the fryer are shown below.
Input Voltage
Current per fryer
NonCE
cooker
burner
120 V Ac, 60Hz
7 Amps
220 (or 240) V Ac, SOliz
3 .s Amps
1-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frialator sf14r ufm

Table of Contents