d. Set the thermostat dial to 32S°F.
e. Remove the thermometer dial by pulling the knob straight out. DO NOT rotate the dial.
f.
Hold the outside of the shaft so it does not move. Use the tip of a small, flat tip screw driver
to scrape away the sealing compound from the adjustment screw.
g. Turn the adjustment screw clockwise to lower the temperature setting and counterclock-
wise to raise the temperature. One quarter turn changes the temperature approximately
25°F.
h.
Turn the adjustment until the burners turn on at 32S°F. Repla~ the knob and allow the
fryer to cycle 4 to 6 times. Check the temperature of the thermometer against the
thermostat dial, if it is greater than 5°F differen~ repeat the calibration procedure.
i. When the calibration is correct, remove the thermometer and rep1aC%
the tube saeen.
HIgh Umit Test
TIllS TEST SHOULD BE PERFORMED
BY
OUAUFIED PER.~ONNEL ONLY
1.5.7