How To Update The Firmware (Mc-3000S); How To Activate The Maintenance Program; How To Confirm The Firmware Program Version - Furuno VR-7000 Instruction Manual

Vdr maintenance viewer
Hide thumbs Also See for VR-7000:
Table of Contents

Advertisement

7. SETTING FOR SENSOR ADAPTER
7.4

How to Update the Firmware (MC-3000S)

This section shows you how to update the firmware program of the sensor adapter
MC-3000S.
Preparation
• PC that has a LAN port
Windows XP
subnet mask of the PC as shown below.
IP address: 172.31.16.200
Subnet mask: 255.255.0.0
• LAN cable
• Binary file for update
2450080-xxxxxxxx_mc_cs_boot.bin
2450081-xxxxxxxx_mc_cs_mainpg.bin
2450082-xxxxxxxx_mc_cs_maint.bin
2450084-xxxxxxxx_mc_io_mainpg.bin
(xxxxxxxx: program version)
7.4.1

How to activate the maintenance program

1. Turn off all sensor adapters.
2. Connect the applicable MC-3000S to the PC with the LAN cable.
3. Turn on the No. 6 of the DIP-SW (S10) on the MC-CS board (24P0114).
4. Turn on the sensor adapter MC-3000S.
5. The maintenance program activates after about 30 seconds. At this time, the IP
address of MC-3000S is changed to "172.31.17.108".
Confirm that the LED (CR 74) on the MC-CS board lights 3 times and goes off for
a while repeatedly.
7.4.2

How to confirm the firmware program version

1. Activate the maintenance program of the sensor adapter MC-3000S.
2. Activate the command prompt of Windows
3. Enter "telnet 172.31.17.108" on the command prompt.
4. Enter the user name and password correctly.
7-8
®
is recommended. Disable the firewall and set the IP address and
Enter the telnet command.
Enter the telnet command.
Enter the telnet command.
Enter the user name.
Enter the user name.
Enter the user name.
Enter the user password.
Enter the user password.
Enter the user password.
Boot program
Main program
Maintenance program
Main program (analog, digital input,
and digital output board)
®
.

Hide quick links: