How To Save The Log File - Furuno VR-7000 Instruction Manual

Vdr maintenance viewer
Hide thumbs Also See for VR-7000:
Table of Contents

Advertisement

10. Check the checkbox of [Channel No.] to set the items referring to the table shown
below.
Item
Sensor Name
Enter an appropriate name that indicates sensor's function.
Data Type
Sets the input data type. Setting range: -10-10V, 0-10V, 4-20mA.
Note: For [4-20mA], fix the jumper to the connector (J3 to J5). See the installation
manual of ECDIS, chart radar, VR-7000.
Details
To display the analog input data on the conning display, click [Details] then check
the check box of [Calibration Active]. Then, enter input voltage (or current) and the
value to show on the conning display, for two points.
Note: For [4-20mA], enter the value by the ampere (A).
In the setting above, "0" is shown on the conning display when analog input is 0 V,
and "120" is shown when analog input is 120 V.
11. To save the configuration, confirm the consistency of the configuration and save
the configuration data on the [Save and Sync] menu.
7.3

How to Save the Log File

The log file of the sensor adapter can be saved to a medium (PC, USB memory, etc.).
The log file is used to check the status of the sensor adapter.
1. Connect the PC to the sensor adapter with the LAN cable.
2. Activate the web browser and enter the following address in the address bar.
"http://172.31.xx.xxx/cgi-bin/logall.cgi"
"172.31.xx.xxx" is the IP address of the sensor adapter where to save the log file.
3. After entering the address, the window to save the log file appears. Save the log
file to the PC.
7. SETTING FOR SENSOR ADAPTER
Remarks
7-7

Hide quick links:

Advertisement

Table of Contents
loading