Technical Data - Elcometer 456 Operating Instructions Manual

Coating thickness gauge
Hide thumbs Also See for 456:
Table of Contents

Advertisement

12 TECHNICAL DATA

12.1 Measurement speed
>60 readings per minute.
This rate is reduced to >40 readings per minute when
Infrared printer output is active - see "OUTPUT:" on
page 21.
When
measuring
measurement speed must be reduced to prevent
overheating of the probe. The maximum measurement
speed of the High Temperature PINIP™ probe at 250°C
(480°F) is 4 readings per minute.
12.2 Minimum substrate thickness
Ferrous: 300 µm (12 mils)
Non-ferrous: 100 µm (4 mils)
Measurements can be taken on thinner substrates if
2-point calibration is carried out either side of the
required substrate thickness, however gauges will have
reduced range when adjusted for thin substrates.
12.3 Probe operating temperature
Separate ferrous probes:
High temperature PINIP™ probes:
Miniature probes without outer sleeve: 150°C (300°F)
All other probes:
12.4 Physical
Weight
(including
batteries):
Dimensions: 130 mm x 70 mm x 35 mm
Gauge
operating
temperature:
Case:
high
Separate Probe (FNF1), 190g (6.7oz)
Separate Probe (PINIP™), 155g (5.5oz)
Integral Probe, 130g (4.6oz)
(5.12" x 2.76" x 1.38")
0°C to 50°C (32°F to 120°F)
Operation outside these limits depends
upon climatic conditions.
High impact ABS
temperature
150°C (300°F)
250°C (480°F)
80°C (176°F)
materials
41