10 TECHNICAL DATA

Range:
Accuracy:
Resolution:
Measurement speed:
Weight:
Dimensions:
Operating temperature (ambient
Operating temperature, maximum (probe):
Storage temperature:
Case:
Batteries:
c.
Whichever is the greater.
d.
Operation outside these limits depends upon climatic conditions. If required, contact Elcometer for further information.
e.
Alkaline batteries must be disposed of carefully to avoid environmental contamination. Please consult your local envi-
ronmental authority for information on disposal in your region.
Do not dispose of any batteries in fire.
f.
Rechargeable batteries can be used if they are charged outside the gauge.
0 µm to 1000 µm (0 mils to 40 mils)
±3% or ±3 µm
1 µm (0.1 mils)
>60 readings per minute
130g (4.1oz)
110 mm x 75 mm x 35 mm (4.3" x 3" x 1.38")
d
):
0°C to 50° C (32°F to 120°F)
80°C (176° F )
-10°C to 55°C (14°F to 130° F)
High impact ABS
2 x LR03 (AAA), alkaline
or rechargeable
c
(±0.12 mil)
e
dry batteries
f
equivalents.
R
11