Statistics; Enlarge Stats - Elcometer 456 Operating Instructions Manual

Coating thickness gauge
Hide thumbs Also See for 456:
Table of Contents

Advertisement

6 STATISTICS

The Elcometer 456
(STATS) which calculates and displays a statistical
analysis of readings as they are taken.
When EXTENDED MENU is active (MENU/EXTENDED
MENU/SEL), press STATS softkey to access STATS
MENU (Figure 30).
The statistical values available are:
Number of Readings
Mean
Standard Deviation
Coefficient of Variation
Highest Reading
Lowest Reading
See
"Select
terminology" on page 40.
If you require statistics in batches, or memory for
readings, Elcometer 456
provide this facility. Contact Elcometer or your local
Elcometer supplier for more details.

6.1 ENLARGE STATS

Displays the chosen statistical values as double-height
characters. The example screens (Figure 31) appear
when all the statistical values are selected. The
32
2
Basic has a Simple Statistics feature
Figure 30. Stats menu
stats"
on
2
page 34
models Standard and Top
and
"Statistics

Advertisement

Table of Contents
loading