Elcometer 456 Operating Instructions Manual page 23

Coating thickness gauge
Table of Contents

Advertisement

4.4.3 CAL METHOD
Allows selection of calibration method from list of options
- see "Calibration method" on page 23 for more details.
4.4.4 SETUP
Used to select, change or activate gauge features:
STATISTICS: Activates simple statistics feature.
Stats softkey on/off.
Select stats - see "Select stats" on page 34.
Display - see "Display" on page 33.
PROBE: Only for dual function probes (FNF and F1 2).
Changes probe mode.
FNF probes - select from Automatic, F or N.
F1 2 probes - select from F1 or F2.
UNITS: Units are automatically set by the probe type,
however the user can manually override the automatic
setting. Select from µm, mm, mil, thou or inch.
OUTPUT: Activates
interface. Toggle tick box to activate/deactivate. When
activated, readings are sent to the infrared portable
printer as they are taken. See "Infrared portable printer"
on page 44 for sales part number of this optional
accessory.
BEEP VOLUME: Changes volume.
0 = off
5 = loudest
Default = 3
LANGUAGES: Allows selection of language.
AUTO SWITCH OFF: Changes delay before gauge
switches off when displaying Reading Screen.
Minimum = 1 minute
Maximum = 10 minutes
Default = 1 minute
Auto switch off may be disabled by selecting 'off' (In this
case, switch off using On/Off key
data
output
via
the
.)
infrared
21