SITRANS F M
8.5.1

Flow rate

8.5.2

Totalizer

8.5.3

Batch

(Only available on
MAG 6000)
Batch cycle counter
Batch cycle counter reset
74
8. Commissioning
The first display line is always active and shows the value enabled in the operator menu setup.
Flow rate
Totalizer 1
Totalizer 2
The second and third display lines are individually set in the operator menu. The page forward key
steps through the enabled settings.
Flow rate
Totalizer
Totalizer reset
Batch control
Batch cycle counter
Batch cycle counter reset
Pipe size
Sensor type
Pending errors
Status log
Tag No.
A totalizer is reset by pressing the lock key when the corresponding totalizer reset window is open.
A batch can be started, paused or stopped from the operator menu, in addition to the externally
operated batch control. The batch is controlled using the lock and the top up keys
The lock key:
Starts the batch
Holds the batch (pause) when pressed during batching
Restarts the batch to continue when pressed during a pause.
The top up key
resets a batch completely during a pause.
The accumulated number of performed batches can be viewed when enabled in the operator menu
setup.
The batch cycle counter is reset by pressing the lock key in the "batch cycle cnt reset" menu.
Operator menu
.