Sensor Mag 3100 - Siemens MAG 1100 F Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for MAG 1100 F:
Table of Contents

Advertisement

SITRANS F M
2.3 Sensor MAG 3100, MAG 3100 HT and MAG 3100 P
Type
MAG 3100
Nominal size
DN 15 ... DN 2000
Measuring principle
Excitation frequency
• DN 15 ... 65 (½" ... 2½"):
(Main supply:
12.5 Hz / 15 Hz
50 Hz / 60 Hz)
• DN 80 ... 150 (3" ... 6"):
6.25 Hz / 7.5 Hz
• DN 200 ... 1200 (8" ... 48"):
3.125 Hz / 3.75 Hz
• DN 1400 ... 2000 (54" ... 78"):
1.5625 Hz / 1.875 Hz
Process connection
Flanges
EN 1092-1, raised face
(EN 1092-1, DIN 2501 & BS 4504
have the same mating dimensions)
• DN 65 ... 2000 (2½" ... 78"):
PN 6 (87 psi)
• DN 200 ... 2000 (8" ... 78"):
PN 10 (145 psi)
• DN 65 ... 2000 (2½" ... 78"):
PN 16 (232 psi)
• DN 200 ... 600 (8" ... 24"):
PN 25 (362 psi)
• DN 15 ... 600 (½" ... 24"):
PN 40 (580 psi)
• DN 50 ... 300 (2" ... 12"):
PN 63 (913 psi)
• DN 25 ... 300 (1" ... 12"):
PN 100 (1450 psi)
ANSI B16.5 (~BS 1560), raised face
• ½" ... 24": Class 150 (20 bar (290 psi))
• ½" ... 24": Class 300 (50 bar (725 psi))
AWWA C-207, flat face 28" ... 78":
Class D (10 bar)
AS 2129, raised face ½" ... 48":
Table E
AS 4087, raised face:
• PN 16 (DN 50 ... 1200, 16 bar (232 psi))
• PN 21 (DN 50 ... 600, 21 bar (304 psi))
• PN 35 (DN 50 ... 600, 35 bar (508 psi))
Other flanges and pressure ratings
on request
Rated operation conditions
Ambient temperature
(conditions also
dependent on liner
characteristiques)
• Sensor
-40 ... +100 °C (-40 ... +212 °F)
• Sensor ATEX
-20 ... +60 °C (-4 ... +140 °F)
• Compact transmitter
MAG 5000/6000
-20 ... +50 °C (-4 ... +122 °F)
2. Technical data
(½" ... 78")
MAG 3100, MAG 3100 HT and MAG 3100 P
MAG 3100 HT (High Temperature)
DN 15 ... DN 300
(½" ... 12")
Electromagnetic induction
• DN 15 ... 65 (½" ... 2½"):
12.5 Hz / 15 Hz
• DN 80 ... 150 (3" ... 6"):
6.25 Hz / 7.5 Hz
• DN 200 ... 300 (8" ... 12"):
3.125 Hz / 3.75 Hz
EN 1092-1, raised face
(EN 1092-1, DIN 2501 & BS 4504
have the same mating dimensions)
• DN 15 ... 300 (½" ... 12"):
PN 40 (580 psi)
• DN 65 ... 300 (2½" ... 12"):
PN 16 (232 psi)
• DN 200 ... 300 (8" ... 12"):
PN 10 (145 psi)
• DN 200 ... 300 (8" ... 12"):
PN 25 (362 psi)
ANSI B16.5 (~BS 1560), raised face:
• ½" ... 12":
Class 150 (20 bar (290 psi))
• ½" ... 12":
Class 300 (50 bar (725 psi))
AS 2129, raised face ½" ... 12":
Table E
Other flanges and pressure ratings
on request
-40 ... +100 °C (-40 ... +212 °F)
For medium temperature up
to 150 °C (302 °F)
-20 ... +60 °C (-4 ... +140 °F)
For medium temperature
150 ... 180 °C (302 ... 356 °F):
-20 ... +50 °C (-4 ... +122 °F)
-20 ... +50 °C (-4 ... +122 °F)
MAG 3100 P
DN 15 ... DN 300
(½" ... 12")
• DN 15 ... 65 (½" ... 2½"):
12.5 Hz / 7.5 Hz
• DN 80 ... 150 (3" ... 6"):
6.25 Hz / 7.5 Hz
• DN 200 ... 300 (8" ... 12"):
3.125 Hz / 3.75 Hz
EN 1092-1, raised face
(EN 1092-1, DIN 2501 & BS 4504
have the same mating dimensions)
• DN 15 ... 50 (½" ... 2"):
PN 40 (580 psi)
• DN 65 ... 300 (2½" ... 12"):
PN 16 (232 psi)
• DN 200 ... 300 (8" ... 12"):
PN 10 (145 psi)
ANSI B16.5 (~BS 1560), raised face
• ½" ... 12":
Class 150 (20 bar (290 psi))
-40 ... +100 °C (-40 ... +212 °F)
-20 ... +50 °C (-4 ... +122 °F)