Siemens MAG 1100 F Operating Instructions Manual page 2

Electromagnetic flowmeters
Hide thumbs Also See for MAG 1100 F:
Table of Contents

Advertisement

SITRANS F M
Siemens Flow Instruments
range of electromagnetic
flowmeters
2
MAG 1100
Size [mm/inch]
DN 2 ... 100/
1
/
" ... 4"
12
Connection
Flangeless
(Sandwich design)
Pressure [bar/psi]
Max. 40/600
−30 ... +200/
Temperature [°C/°F]
−20 ... 400
Liner
Zirconium oxide
(Zr0
Ceramic (Al
PFA
Electrodes
Platinum
Hastelloy C
Enclosure
IP67/NEMA 4X
Ex-version
ATEX 2G D
FM Class 1, Div 2
Outputs
Flow direction
Communication
Display
Meter uncertainty
Enclosure
NEMA 6 (NEMA 4X), NEMA 2
Custody transfer
approval
Approvals
Power supply
Batch
Refer to
SFIDK.PS.027.W6.02
MAG 1100 F
DN 10 ... 100/
3
/
" ... 4"
8
Weld-in adapter,
clamp adapter,
thread adapter
Max. 40/600
−30 ... +150/
−20 ... 300
Ceramic (Al
O
),
Neoprene, EPDM,
2
3
)
PFA
2
O
),
2
3
Platinum
Hastelloy C
Titanium, Tantalum,
Grounding electrodes
IP67/NEMA 4X
ATEX 2G D
FM Class 1, Div 2
FM/CSA Class 1, Div 2 FM/CSA Class 1, Div 2
MAG 5000
1 current output
1 digital output
1 relay output
Uni/bidirectional
®
Optional HART
3 lines
20 characters
(optional without display)
±0.4% o.r.
IP67, IP20
MI-001
PTB
OIML R 49
ATEX 2G D
FM/CSA Class 1, Div 2
12 ... 24 V AC/DC
115 ... 230 V AC
No
MAG 6000 Industry
Operating manual
A5E02083319
MAG 3100
MAG 3100 P
DN 15 ... 2000/
DN 15 ... 300/
1
1
/
" ... 78"
/
" ... 12"
2
2
Flange
Flange
Max. 100/1450
Max. 50/725
−40 ... +180/
−20 ... +150/
−40 ... 350
−4 ... 300
PTFE, PFA
Teflon (PTFE),
Ebonite,
®
Linatex
PFA
AISI 316 Ti,
Hastelloy C
Hastelloy C,
Platinum/iridium,
IP67/IP68
IP67/IP68
NEMA 4X/6 /
NEMA 4X/6 /
NEMA 6P
NEMA 6P
ATEX 2G D
ATEX 2G D
MAG 6000
1 current output
1 digital output
1 relay output
Uni/bidirectional
Add-on modules,
HART, Profibus PA & DP,
MODBUS RTU, DeviceNet, Foundation Fieldbus H1
3 lines
20 characters
(optional without display)
±0.20% o.r.
IP67, IP20
NEMA 6 (NEMA 4X), NEMA 2
MI-001
PTB (hot and cold water)
OIML R 49
OIML R 75
OIML R 117
ATEX 2G D
FM/CSA Class 1, Div 2
12 ... 24 V AC/DC
115 ... 230 V AC
Yes
MAG 8000
Operating manual
083R9174
MAG 5100 W
DN 25 ... 2000/
1
" ... 78"
Flange
Max. 40/600
−10 ... +70/
−14 ... 160
EPDM, NBR,
Ebonite
Hastelloy C,
Grounding
electrodes
IP67/IP68
NEMA 4X/6 /
NEMA 6P
FM Class 1,
Div 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 1100Mag 3100Mag 3100 pMag 5000Mag 6000Mag 5100 w

Table of Contents