Sensor Mag 5100 W - Siemens MAG 1100 F Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for MAG 1100 F:
Table of Contents

Advertisement

SITRANS F M

2.4 Sensor MAG 5100 W

Technical specifications
Product characteristic:
Design and nominal size
Measuring principle
Excitation frequency
(Mains supply: 50 Hz/60 Hz)
Process connection
Flanges
EN 1092-1
ANSI B16.5
AWWA C-207
AS4087
JIS B 2220:2004 -
Rated Operation conditions
Ambient temperature
Sensor
With compact transmitter
MAG 5000/6000
With compact transmitter MAG 6000 I -20 ... +60
Operating pressure (Abs)
[abs. bar] (maximum operating
pressure decreases with increasing
operating temperature)
Enclosure rating
Standard
Option
Pressure drop at 3 m/s (10 ft/s)
Test pressure
Mechanical load
Medium conditions
Temperature of medium
NBR
EPDM
Ebonite
EMC
For sizes larger than 600 mm (24") in PN 16, PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and
1)
EMC approvals.
16
2. Technical data
EPDM or NBR lining (Order No. 7ME6520)
Targeted towards the EU water markets and
low flow applications:
Full bore sensor: DN 25 ... 40 (1" ... 1½")
Coned sensor: DN 50 ... 300 (2" ... 12")
Full bore sensor: DN 350 ... 1200 (14" ... 48")
Electromagnetic induction
DN 25 ... 65 (1" ... 2½"): 12.5 Hz /15 Hz
DN 80 ... 150 (3" ... 6"): 6.25 Hz /7.5 Hz
DN 200 ... 300 (8" ... 12"): 3.125 Hz / 3.75 Hz
DN 350 ... 1200 (14" ... 48"): 1.5625 Hz /1.875 Hz
PN 10 (145 psi): DN 200 ... 300 (8" ... 12"):
Flat face flanges
PN 10 (145 psi): DN 350 ... 1200 (14" ... 48"):
Raised face flanges
PN 16 (232 psi): DN 50 ... 300 (2" ... 12"):
Flat face flanges
PN 16 (232 psi): DN 350 ... 1200 (14" ... 48"):
Raised face flanges
PN 40 (580 psi): DN 25 ... 40 (1" ... 1½"):
Raised face flanges
Class 150 lb: 1" ... 24":
Class D:
28"
... 48", Flat face
PN 16 (DN 50 ... 1200), (2" ... 48")
16 bar (232 psi)
°C
(-40 ... +158 °F)
-40 ... +70
°C
(-4 ... +122 °F)
-20 ... +50
°C
(-4 ... +140 °F)
DN 25 ... 40 (1" ... 1½"):
0.01 ... 40 bar (0.15 ... 580 psi)
DN 50 ... 300 (2" ... 12"):
0.03 ... 20 bar (0.44 ... 290 psi)
DN 350 ... 1200 (14" ... 48"):
0.01 ... 16 bar (0.15 ... 232 psi)
IP67 to EN 60529 / NEMA 4X/6
(1 mH2O for 30 min)
IP68 to EN 60529 / NEMA 6P
(10 mH2O continuously)
DN 25 ... 40 (1" ... 1½"): As straight pipe
DN 50 ... 300 (2" ... 12"): Max. 25 mbar (0.36 psi)
DN 350 ... 1200 (14" ... 48"): As straight pipe
1.5 x PN (where applicable)
18 ... 1000 Hz random in x, y, z, directions for 2
hours according to EN 60068-2-36
Sensor: 3.17 grms
Sensor with compact MAG 5000/6000 mounted
transmitter: 3.17 grms
Sensor with compact MAG 6000 I mounted
transmitter: 1.14 grms
- 10 ... +70 °C (14 ... 158 °F)
- 10 ... +70 °C (14 ... 158 °F)
-
89/336 EEC
Ebonite lining (Order No. 7ME6580)
Targeted towards the Non EU water markets
Full bore sensor: DN 25 ... 2000 (1" ... 78")
Electromagnetic induction
DN 25 ... 65 (1" ... 2½"): 12.5 Hz /15 Hz
DN 80 ... 150 (3" ... 6"): 6.25 Hz /7.5 Hz
DN 200 ... 1200 (8" ... 48"): 3.125 Hz / 3.75 Hz
DN 1400 ... 2000 (54" ... 78"): 1.5625 Hz /1.875 Hz
Raised face (EN 1092-1, DIN 2501 and BS 4504
have the same mating dimensions)
PN 6 (87 psi): DN 1400 ... 2000 (54" ... 78")
PN 10 (145 psi): DN 200 ... 2000 (8" ... 78")
PN 16 (232 psi): DN 65 ... 600 (2" ... 24")
PN 40 (580 psi): DN 25 ... 50 (1" ... 2")
1" ... 24": Class 150 lb
Class D: 28" ... 78"h, Flat face
PN 16 (DN 50 ... 1200), (2" ... 48")
16 bar (232 psi)
K10 (1" ... 24")
-20 ... +70 °C (-4 ... +158 °F)
-20 ... +50 °C (-4 ... +122 °F)
-20 ... +60 °C (-4 ... +140 °F)
DN 25 ... 50 (1" ... 2"):
0.01 ... 40 bar (0.15 ... 580 psi)
DN 65 ... 1200 (2½" ... 48"):
0.01 ... 16 bar (0.15 ... 232 psi)
DN 1400 ... 2000 (54" ... 78"):
0.01 ... 10 bar (0.15 ... 145 psi)
IP67 to EN 60529 / NEMA 4X/6
(1 mH2O for 30 min)
IP68 to EN 60529 / NEMA 6P
(10 mH2O continuously)
As straight pipe
1.5 x PN (where applicable)
18 ... 1000 Hz random in x, y, z, directions for
2 hours according to EN 60068-2-36
Sensor: 3.17 grms
Sensor with compact MAG 5000/6000 mounted
transmitter: 3.17 grms
Sensor with compact MAG 6000 I mounted
transmitter: 1.14 grms
-
-
- 10 ... +70 °C (14 ... 158 °F)
89/336 EEC
MAG 5100 W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 1100Mag 3100Mag 3100 pMag 5000Mag 6000Mag 5100 w

Table of Contents