SITRANS F M
3.2.1

Minimum conductivity

3.2.2

Liner selection guide

3.2.3

Electrode selection guide

3.3

Installation conditions

3. Project guidance
Applications
Compact/remote
DN 2 & 3 (DN ≥
1
/
&
1
/
12
8
DN ≥ 6 (DN ≥
¼ inch)
With empty pipe detection
Ex-installations
(Remote mounted only)
District heating systems
(Without DC cleaning unit)
Liner
Zirconium oxide ZrO
2
Ceramics Al
O
2
3
PFA
Neoprene
EPDM
PTFE
® ® ® ® ®
Linatex
Ebonite
NBR:
Electrodes
AISI 316 Ti
Hastelloy C
Titanium
Tantalum
Platinum and platinum/irridium
Min. conductivity
inch)
30 µS/cm
5 µS/cm
50 µS/cm
30 µS/cm
250 µS/cm
max. 150 ft
Applications
General purpose, agressive chemicals
General purpose, food and beverage, agressive chemicals
General purpose, food and beverage, pulp and paper, chemicals,
high temperature and chemical resistance
Water and wastewater and some chemical applications
Drinking water applications, (not hydrocarbons)
Chemical and general process industries, high temperature and
chemical resistance
Abrasive media and mining slurries
Drinking water applications, wastewater applications and certain
chemical applications
General purpose, Drinking water, sea water
Applications
General purpose, water, sewage and district heating
The preferred choice for water and wastewater, chemicals, food
and beverage, and pharmaceutical industries
Process and chemical industry which require a high corrosion
resistance
Chemical industry with aggressive media
The ultimate electrode material unaffected by most liquids
Reading and operating the flowmeter is possi-
ble under almost any installation conditions
because the display can be oriented in relation
to the sensor. To ensure optimum flow mea-
surement, attention should be paid to the fol-
lowing: