July 2017
Figure 4. Rosemount 5708 Connection
RS-485 (+)
120 Ω
RS-485 (-)
Figure 5. 4-20 mA Connection
4-20 mA
Active
This type of connection is active and not passive, hence the device is the active module and the PLC should
be the passive module.
4.0

Configuration using the LCD display

4.1 On-board configuration
The Rosemount 5708L can be completely configured via the LCD display.
For the Rosemount 5708V and 5708S, the Rosemount 3DVision software is
required.
Figure 6. User Interface
Rosemount
Rosemount
5708 2
5708 1
Passive
Navigates back within a function menu.
ESC
Continuous 3 second press exits to the default screen.
Navigates upwards in the navigation list.
Navigates right within a function.
Navigates downwards in the navigation list.
Navigates left within a function.
Navigates to the right when within a function group.
E
Stores a value once configured.
Rosemount
5708 3
PLC / Controller
Quick Start Guide
Rosemount
5708 n
RS-485 (+)
120 Ω
RS-485 (-)
15