July 2017
7.0
Rosemount 5708S in a system
7.1
System components
Multiple units of Rosemount 5708S
PS IN 4...20mA
+
- -
+
PLC / DCS / Display
4-20 mA is a 2 wire,
non-loop powered,
active device connection
Rosemount System Controller
7.2
Physical mounting
1. Install the devices as written in
2. Repeat installation steps until all are installed.
7.3
Wiring
Power
A single 24 Vdc power supply is for all devices within the system.
Display
PS IN 4...20mA
PS OUT
RS-485
+
- -
+
+
-
+
-
RS-485
+
-
120
resistor
PS IN 4...20mA
+
PS IN 4...20mA
+
- -
+
Ω
Rosemount 3DVision Server
24 Vdc
power
supply
"Physical mounting" on page
Quick Start Guide
Display
PS OUT
RS-485
- -
+
+
-
+
-
RS-485
+
-
120
Convert
8.
Ω
resistor
27